Validation and Application of a Dried Blood Spot Amoxicillin Assay

Madhu Page-Sharp,Okhee Yoo,Sam Salman,Timothy M. E. Davis,Brioni R. Moore,Laurens Manning,Kevin T. Batty
DOI: https://doi.org/10.1007/s10337-024-04341-z
2024-05-17
Chromatographia
Abstract:Dried blood spot (DBS) antibiotic assays can facilitate pharmacokinetic (PK) investigations in situations where venous blood sampling is logistically and/or ethically challenging. The aim of this study was to establish, validate and demonstrate the application of a DBS amoxicillin assay for PK studies in vulnerable populations. The matrix effect, process efficiency (84–104%) and recovery (85–110%) of the liquid chromatography–mass spectrometry (LC–MS/MS) assay for amoxicillin in DBS was determined at 1, 10 and 100 μg/mL, and three different haematocrits. Thermal stability studies of amoxicillin in DBS were performed and a bridging study comprising 26 paired plasma and DBS samples was conducted in four healthy individuals. The limits of detection and quantification were 0.02 and 0.05 μg/mL for plasma and DBS amoxicillin assays, respectively. Accuracy and interday precision of amoxicillin in DBS (0.1–100 μg/mL) were 88–103% and 4.5–9.2%, respectively. At room temperature (22 °C) and 4 °C, amoxicillin was stable in DBS for ≈4 and 26 h, respectively. There was no degradation of amoxicillin in DBS at −20 °C for > 6 months. When comparing DBS and plasma collected from healthy volunteers, the slope of the Deming regression was 0.74. Amoxicillin CL/F estimates from DBS and plasma concentration data were 40.8 and 30.7 L/h/70 kg, respectively; V/F was 43.2 and 37.4 L/70 kg, respectively. In conclusion, amoxicillin can be reliably assayed from DBS in research studies but may have limited application in therapeutic drug monitoring. Due to poor stability at room temperature, amoxicillin DBS samples should be promptly dried and placed in frozen storage.
chemistry, analytical,biochemical research methods
What problem does this paper attempt to address?
The paper aims to establish, validate, and demonstrate the application of a dried blood spot (DBS) amoxicillin detection method for pharmacokinetic (PK) studies in vulnerable populations. Specifically, the researchers developed a DBS amoxicillin detection method based on liquid chromatography-tandem mass spectrometry (LC-MS/MS) and conducted comprehensive validation, including the evaluation of performance parameters such as matrix effects, process efficiency, and recovery rates. Additionally, the study included thermal stability testing and bridging studies to compare amoxicillin concentrations and PK parameters in DBS and plasma samples from healthy individuals. The core issue of the paper is to provide a reliable and convenient method for detecting amoxicillin concentrations by addressing the logistical and ethical challenges of traditional venipuncture, especially in vulnerable or immobile patient groups. This not only helps optimize antibiotic dosing and improve clinical efficacy but also reduces the threat of antibiotic resistance.