Fluorescence lifetime imaging with distance and ranging using a miniaturised SPAD system

Andrew B. Matheson,Charlotte Hopkinson,Michael G. Tanner,Robert K. Henderson
DOI: https://doi.org/10.1038/s41598-024-63409-w
IF: 4.6
2024-06-12
Scientific Reports
Abstract:In this work we demonstrate a miniaturised imaging system based around a time-gated SPAD array operating in a "chip-on-tip" manner. Two versions of the system are demonstrated, each measuring 23 mm × 23 mm × 28 mm with differing fields of view and working distances. Initial tests demonstrate contrast between materials in widefield fluorescence imaging (WFLIm) mode, with frame rates of > 2 Hz achievable. Following this, WFLIm images of autofluorescence in ovine lung tissue are obtained at frame rates of ~ 1 Hz. Finally, the ability of the second system to perform simultaneous WFLIm and time of flight (aka Flourescence Lifetime Imaging Distance and Ranging, FLImDAR) is also tested. This shows that the system is capable of 4 mm resolution of object separation when tested on 3D printed samples. It is further demonstrated as being able to perform scene reconstruction on autofluorescent lung tissue. This system is, to date, the smallest chip on tip WFLIm system published, and is the first demonstration of the FLImDAR technique in a compact, portable system.
multidisciplinary sciences
What problem does this paper attempt to address?
The main problem that this paper attempts to solve is to develop a miniaturized imaging system. This system is based on time - gated single - photon avalanche diode (SPAD) arrays and can operate in a "chip - on - tip" manner. Specifically, the paper presents two versions of the system, each with a size of 23 mm × 23 mm × 28 mm but having different fields of view and working distances. These systems are designed to achieve wide - field fluorescence lifetime imaging (WFLIm) and fluorescence lifetime imaging and ranging (FLImDAR), that is, to simultaneously acquire fluorescence lifetime and distance information, to provide additional contrast for materials or tissues, and to be able to perform 3D scene reconstruction. ### Main problems and objectives: 1. **Miniaturized imaging system**: Develop a smaller and more portable WFLIm system for in - vivo applications (such as endoscopy). 2. **Fluorescence lifetime imaging**: Improve the contrast between different materials or tissues through fluorescence lifetime imaging technology, especially using autofluorescence for imaging in sheep lung tissues. 3. **Fluorescence lifetime imaging and ranging (FLImDAR)**: Implement FLImDAR technology for the first time in a compact handheld system, that is, simultaneously acquire fluorescence lifetime and distance information for 3D scene reconstruction and surface mapping. 4. **Application scenarios**: Explore the potential applications of this system in biomedical imaging (such as endoscopy, surgical navigation, diagnostic imaging), agriculture (such as plant health monitoring) and other fields. ### Technical highlights: - **Time - gated SPAD arrays**: Using time - gated SPAD arrays, the fluorescence decay curve can be captured at a fine time resolution, thereby calculating the fluorescence lifetime. - **Rapid lifetime determination (RLD) method**: The fluorescence lifetime is approximately calculated by comparing the intensity ratios at two different time - gate positions. The formula is as follows: \[ \tau = -\frac{\Delta t}{\ln\left(\frac{I_1}{I_2}\right)} \] where \(\tau\) is the calculated fluorescence lifetime, \(\Delta t\) is the size of the time gate, and \(I_1\) and \(I_2\) are the intensities at the first and second time - gate positions respectively. - **Multi - mode imaging**: Combine WFLIm and ToF data to achieve 3D scene reconstruction and surface mapping. ### Experimental results: - **WFLIm test**: Preliminary tests were carried out on 3D - printed fluorescent samples, and the results showed good contrast between different materials. - **Sheep lung tissue imaging**: WFLIm and FLImDAR imaging were successfully performed on sheep lung tissues, showing the differences in fluorescence lifetimes of different tissue types. - **3D point cloud generation**: A 3D point cloud of sheep lung tissue was generated through FLImDAR technology, demonstrating the ability to simultaneously measure distance and fluorescence lifetime. ### Conclusion: This study shows the potential of miniaturized time - resolved imaging sensors in in - vivo applications, especially in the field of biomedical imaging. Although the current system is still slow in acquisition time, its spatial resolution on bright samples is about 4 mm, and it can simultaneously acquire distance and fluorescence lifetime information, indicating that FLImDAR technology has broad application prospects in micro - endoscopy imaging.