Random Body Movement Removal Using Adaptive Motion Artifact Filtering in mmWave Radar-Based Neonatal Heartbeat Sensing

Shiguang Yang,Xuerui Liang,Xiangwei Dang,Nanyi Jiang,Jiasheng Cao,Zhiyuan Zeng,Yanlei Li
DOI: https://doi.org/10.3390/electronics13081471
IF: 2.9
2024-04-13
Electronics
Abstract:In response to the pressing requirement for prompt and precise heart rate acquisition during neonatal resuscitation, an adaptive motion artifact filter (AMF) is proposed in this study, which is based on the continuous wavelet transform (CWT) approach and takes advantage of the gradual, time-based changes in heart rate. This method is intended to alleviate the pronounced interference induced by random body movement (RBM) on radar detection in neonates. The AMF analyzes the frequency components at different time points in the CWT results. It extracts spectral peaks from each time slice of the frequency spectrum and correlates them with neighboring peaks to identify the existing components in the signal, thereby reducing the impact of RBM and ultimately extracting the heartbeat component. The results demonstrate a reliable estimation of heart rates. In practical clinical settings, we performed measurements on multiple neonatal patients within a hospital environment. The results demonstrate that even with limited data, its accuracy in estimating the resting heart rate of newborns surpasses 97%, and during infant movement, its accuracy exceeds 96%.
engineering, electrical & electronic,computer science, information systems,physics, applied
What problem does this paper attempt to address?
The main problem that this paper attempts to solve is the significant interference problem caused by random body movement (RBM) during neonatal heart rate detection. Specifically: 1. **Background and Challenges**: - During neonatal resuscitation, obtaining the heart rate quickly and accurately is crucial. Although traditional contact methods such as auscultation, palpation, pulse oximetry, and electrocardiogram estimation have a certain degree of accuracy, they have problems such as time delay or inaccurate measurement. - Non - contact detection methods such as optical cameras, WiFi, and radar detection face challenges such as environmental interference and signal overlap in practical applications. 2. **Research Objectives**: - Propose an adaptive motion artifact filtering (AMF) based on continuous wavelet transform (CWT) to reduce the impact of random body movement on neonatal heartbeat detection by millimeter - wave radar. - By analyzing the frequency components at different time points in the CWT results, extract the spectral peaks and correlate them with adjacent peaks, thereby identifying the existing components in the signal, and finally extract the heartbeat components. 3. **Innovations**: - Utilize the gradually changing characteristics of the heartbeat frequency to propose a new AMF method, which can improve the quality of heart rate measurement in the presence of RBM. - By analyzing the time - frequency information on the chest surface, separate the spectra of RBM and heartbeat, and extract the continuously changing heartbeat spectrum in the time domain to reduce the influence of RBM. 4. **Experimental Verification**: - Measurements were carried out on multiple neonatal patients in a hospital environment, and the results showed that the heart rate estimation accuracy of this method exceeded 96% even when the infants were active. In summary, this paper aims to achieve more accurate and reliable neonatal heart rate detection by developing a new AMF method and using millimeter - wave radar technology, especially in the presence of random body movement.