Effective monitoring of environmental hazardous drug moxifloxacin hydrochloride in aquatic and biological samples using silver selenide on octadecyl amine modified reduced graphene oxide composite

Kuo-Yuan Hwa,Anindita Ganguly
DOI: https://doi.org/10.1016/j.jece.2023.111694
IF: 7.7
2023-12-14
Journal of Environmental Chemical Engineering
Abstract:The precise detection of antibiotics is very critical. Here, silver selenide (Ag 2 Se) nanorods hydrothermally synthesized and ultrasonically treated with rGO surface modified with ODA alkyl amine (rGO-ODA). The optical, structural, morphological, and functional analysis were performed which revealed the orthorhombic pattern of the P2221 E space group, the crystalline purity of the nanorods, and the substantial composite formation. The morphological studies revealed nanorod like structure of the Ag 2 Se material and wrinkled sheets of rGO-ODA. A sensor that detects moxifloxacin hydrochloride (MOXH) antibiotic using the cyclic voltammetry (CV), differential pulse voltammetry (DPV) and UV-Vis absorbance was developed. For DPV analysis, a quite low value for detection limit 12.46 nM was exhibited with 0.199 μM – 425.16 μM linear range, and a sensitivity of 5.0439 μA M -1 cm -2 . For UV-Vis, the sensor demonstrated a very low limit of detection 17.42 nM over 0.12 μM – 7.7 μM working range. The use of this sensor was validated in real-time analysis with industrial waste water, fish, human blood, and urine. The results suggested an excellent rate of analyte recovery and enhanced efficiency for MOXH detection with a potential for commercialization in the future.
engineering, chemical, environmental
What problem does this paper attempt to address?