On‐Patient Temporary Medical Record for Accurate, Time‐Sensitive Information at the Point of Care

Joe Collins,Jooli Han,Morteza Sarmadi,Stephanie Allison‐Logan,Aurelien vander Straeten,Collin F. Perkinson,Sarah Acolaste,Maria Kanelli,John Daristotle,Ari Karchin,Mitchell Henderson,Mache Cruz,Dolev Artzi,Shahad K. Alsaiari,Linzixuan Zhang,Lauren Levy,Lowell Wood,Lihong Jing,Kevin J. McHugh,Moungi G. Bawendi,Robert Langer,,Ana Jaklenec
DOI: https://doi.org/10.1002/adfm.202311821
IF: 19
2024-01-06
Advanced Functional Materials
Abstract:Accurate on‐patient medical recordkeeping reduces medical errors and improves medical adherence. Herein, information is stored in near infrared fluorescent quantum dot‐based patterns distributed on dissolvable microneedle arrays. The patterns are invisible to the naked eye when delivered intradermally but detectable using an infrared camera with automated pattern recognition software. The information can be extracted and conveyed in both spatial and temporal manners. Accurate medical recordkeeping is important for personal and public health. Conventional forms of on‐patient medical information, such as medical alert bracelets or finger‐markings, may compromise patient privacy because they are readily visible to other people. Here, the development of an invisible, temporary, and easily deployable on‐patient medical recordkeeping system is reported. Information is stored in unique patterns of spatially distributed near‐infrared (NIR) fluorescent quantum dots (QDs), which are delivered to the skin using dissolvable microneedle arrays. The patterns are invisible to the naked eye but detectable with an infrared camera, which can extract information with >98% accuracy using automated pattern recognition software. By encapsulating NIR QDs in an FDA‐approved biodegradable polymer, biodegradation rates can be tuned so that the encoded medical information can be conveyed in both a spatial and temporal manner, with some components fading within 100 days and others persisting for 6 months. This may be particularly useful for administering a series of vaccinations or treatments by indicating if enough time has passed for the patient to receive the next dose. Importantly, this system contains no personal information, does not require connection to a centralized database, and is not visible to the naked eye, ensuring patient privacy.
materials science, multidisciplinary,chemistry, physical,physics, applied, condensed matter,nanoscience & nanotechnology
What problem does this paper attempt to address?