Automated and real-time validation of gastroesophageal varices under esophagogastroduodenoscopy using a deep convolutional neural network: a multicenter retrospective study (with video)

Mingkai Chen,Jing Wang,Yong Xiao,Lianlian Wu,Shan Hu,Shi Chen,Guodong Yi,Wei Hu,Xianmu Xie,Yijie Zhu,Yiyun Chen,Yanning Yang,Honggang Yu
DOI: https://doi.org/10.1016/j.gie.2020.06.058
IF: 10.396
2021-02-01
Gastrointestinal Endoscopy
Abstract:<h3 class="u-h4 u-margin-m-top u-margin-xs-bottom">Background and Aims</h3><p>Rupture of gastroesophageal varices is the most common fatal adverse event of cirrhosis. Esophagogastroduodenoscopy (EGD) is considered the criterion standard for diagnosis and risk stratification of gastroesophageal variceal bleeding. The aim of this study was to train and validate the real-time deep convolutional neural networks system (DCNNs), named ENDOAGGEL, for diagnosing gastroesophageal varices and predicting the risk of rupture.</p><h3 class="u-h4 u-margin-m-top u-margin-xs-bottom">Methods</h3><p>After being trained with 8566 images of endoscopic gastroesophageal varices from 3021 patients and 6152 images of normal esophagus/stomach from 3168 patients, ENDOANGEL was also tested with independent images and videos. Besides, it was compared with endoscopists in several aspects.</p><h3 class="u-h4 u-margin-m-top u-margin-xs-bottom">Results</h3><p>ENDOANGEL, in contrast with endoscopists, displayed higher accuracy of 97.00% and 92.00% in terms of detecting esophageal varices (EV) and gastric varices (GV) in image contest. (97.00% vs 93.94% , <em>p</em>&lt;0.01; 92.00% vs 84.43% , <em>p</em>&lt;0.05). It also surpassed endoscopists in red color signs of EV and red spots of GV (84.21% vs 73.45%, <em>p</em> &lt;0.01; 85.26% vs 77.52%, <em>p</em> &lt;0.05). Moreover, ENDOANGEL achieved comparable performance in the determination of size, form, color, and bleeding signs. ENDOANGEL also had good performance in making treatment suggestions. Last but not least, when it comes to predicting risk factors in multicenter videos, ENDOANGEL showed great stability as well.</p><h3 class="u-h4 u-margin-m-top u-margin-xs-bottom">Conclusions</h3><p>Our data suggested that DCNNs were precise in detecting both EV and GV and performed excellently in uncovering the endoscopic risk factors of gastroesophageal variceal bleeding. Thus, the application of DCNNs will assist endoscopists evaluate gastroesophageal varices more objectively and precisely.</p>
gastroenterology & hepatology
What problem does this paper attempt to address?