Allograft Model of Aortic Arch Segment Grafting to Abdominal Aorta Through End-to-Side Anastomosis in Mice

Chiyu Liu,Qi Chen,Mingyuan He,Yulin Liao
DOI: https://doi.org/10.1007/s12265-024-10495-w
2024-02-28
Journal of Cardiovascular Translational Research
Abstract:The mouse aortic transplantation model is a valuable tool for investigating the mechanisms of atherosclerosis regression, but few laboratories can generate it due to the operation difficulty, especially for the style of end-to-side anastomosis, which facilitates syngeneic heterotopic transplanting a plaque-rich aortic arch into the abdominal aorta. Here we provide a modified protocol for generating this allograft model, which is capable of overcoming several critical surgical challenges such as separating a longer abdominal aorta segment, reducing bleeding and thrombosis, optimizing aortotomy, and improving end-to-side anastomosis to guarantee a potent graft. By transplanting plaque-rich aortic arches into the abdominal aorta of wildtype mice, a high operation success rate (over 90%) was noted with aortic clamping time under 60 min, the graft potency was satisfactory evidenced by examinations of micro-CT, ultrasound, and lower limb blood flow measurement, while a significant atherosclerosis regression was observed in the grafts at 1 week after transplantation.
cardiac & cardiovascular systems,medicine, research & experimental
What problem does this paper attempt to address?
The problem that this paper attempts to solve is the technical difficulties in the mouse aortic transplantation model, especially the technical challenges of end - to - side anastomosis. Specifically, the author provides a modified surgical protocol to overcome several key surgical challenges, such as isolating a longer segment of the abdominal aorta, reducing bleeding and thrombosis, optimizing aortotomy, and improving end - to - side anastomosis to ensure effective transplantation. By transplanting the plaque - rich aortic arch into the abdominal aorta of wild - type mice, this study aims to provide a valuable tool for the study of atherosclerotic plaque regression. The key points of the paper include: - **Technical challenges**: The paper describes in detail how to perform aortic arch transplantation in mice, especially the challenges faced when performing end - to - side anastomosis, such as separating the abdominal aorta from the inferior vena cava (IVC), reducing bleeding and thrombosis, optimizing aortotomy, and increasing the success rate of end - to - side anastomosis. - **Operation success rate**: Through the modified surgical protocol, the author reports an operation success rate of over 90% and an aortic clamping time of less than 60 minutes. - **Transplantation effect evaluation**: One week after transplantation, the transplantation effect was evaluated by methods such as micro - CT, ultrasonography, and lower limb blood flow measurement. The results showed a significant reduction in atherosclerotic plaques at the transplantation site, demonstrating the effectiveness of this model. In conclusion, the main objective of this paper is to provide a reproducible, modified mouse aortic arch transplantation model for studying the regression mechanism of atherosclerotic plaques, thereby providing new research directions for the treatment of related diseases.