Accurate and ultrasensitive detection for PEDV based on photoelectrochemical sensing coupling loop-mediated isothermal amplification

Honghong Hong,Ruishuang Yuan,Hanyu Ma,Liting Xiao,Bin Li,Kun Wang
DOI: https://doi.org/10.1016/j.talanta.2023.124476
IF: 6.1
2023-03-29
Talanta
Abstract:Porcine epidemic diarrhea (PED) is a serious disease requiring a simple and accurate detection method. Accordingly, this study developed a novel, ultrasensitive photoelectrochemical (PEC) sensing platform using the loop-mediated isothermal amplification (LAMP) technique (LAMP-PEC). An amino (−NH 2 )-modified LAMP product is obtained by amplification of the PED virus gene with specially designed primers. The generated NH 2 -modified LAMP product is assembled on the surface of an electrode by forming imine linkages between aldehyde and amino groups based on the Schiff base reaction. A stable photocurrent is provided by a CdIn 2 S 4 photoactive material, which possesses high photoelectric conversion efficiency. Amplified DNA assembled on the electrode surface increases steric hindrance and hinders electrons from moving from the electrode to electron acceptors, which decreases the photocurrent. This strategy can detect PEDV with a low detection limit of 0.3 fg μL −1 and a wide linear range of 1 × 10 −3 -1 × 10 2 pg/μL. The sensing platform has excellent specificity and sensitivity and can be used for the quantitative detection of many other pathogens with the assistance of LAMP.
chemistry, analytical
What problem does this paper attempt to address?