Dissociation Phenomenon of Erythrocyte Agglutination and Its Application to Assay of Functional Activity of the Complement System in Clinical Laboratory

Xuewei Ding,Lina Liu,Guang Yang,Hui Liu
DOI: https://doi.org/10.1002/jcla.25028
IF: 3.124
2024-03-22
Journal of Clinical Laboratory Analysis
Abstract:Discovered the phenomenon of dissociated erythrocyte agglutination based on erythrocyte fragments. Established a method to evaluate the functional activity of the complement system by exploiting the dissociation phenomenon of erythrocyte agglutination and using an auto hematology analyzer for combined detection of total complement activity (AC) and complement activators activated complement activity (ACA). The results of this method are highly accurate and reliable. It has the capability to not only screen for diseases but also differentiate between different types of diseases. Objective The objective of the study was to validate the dissociation phenomenon of erythrocyte agglutination which is based on erythrocyte fragments and to apply it in the functional activity assay of the complement system. Methods The dissociation–agglutination effect of erythrocyte fragments was validated by detecting the number of free erythrocytes after the action of erythrocyte fragments on agglutinated erythrocytes. The number of free erythrocytes produced after hemolysis of agglutinated erythrocytes caused by complements and complement activators(CAs) was detected by auto hematology analyzer and the results were indicated by mean hemoglobin concentration of erythrocytes (MCHC). We optimized the test conditions and validated the inter‐batch stability, explored the resolution of the assay method, and assayed for the total complement activity (AC) and the CAs activated complement activity (ACA) in serum from patients and healthy individual groups. Results Erythrocyte fragments have a dissociative effect on agglutinated erythrocytes. The auto hematology analyzer was able to detect AC and ACA, where AC showed an inverse correlation with MCHC, and ACA demonstrated a positive correlation with MCHC. The inter‐batch CV of AC, ACA, and ACA/AC was found to be 5%, 9%, and 11.7%, respectively, with good stability. The study found that serum samples from acute phase reaction patients showed significant differences in ACA compared with healthy individuals, with a p value of 0.018; serum samples from patients with nephrotic syndrome showed significant differences in AC, ACA, and ACA/AC compared with healthy individuals, with p values of 0.014, 0.002, and 0.041, respectively. Conclusion Erythrocyte fragments have dissociation–agglutination effect. The complement system immunological functional detection method, based on this effect, has potential clinical application value due to its sensitivity and accuracy.
medical laboratory technology
What problem does this paper attempt to address?