Flexible, biodegradable ultrasonic wireless electrotherapy device based on highly self-aligned piezoelectric biofilms

Haoyue Xue,Jing Jin,Zhi Tan,Keliang Chen,Gengxi Lu,Yushun Zeng,Xiaolin Hu,Xingchen Peng,Laiming Jiang,Jiagang Wu
DOI: https://doi.org/10.1126/sciadv.adn0260
IF: 13.6
2024-06-01
Science Advances
Abstract:Biodegradable piezoelectric devices hold great promise in on-demand transient bioelectronics. Existing piezoelectric biomaterials, however, remain obstacles to the development of such devices due to difficulties in large-scale crystal orientation alignment and weak piezoelectricity. Here, we present a strategy for the synthesis of optimally orientated, self-aligned piezoelectric γ-glycine/polyvinyl alcohol (γ-glycine/PVA) films via an ultrasound-assisted process, guided by density functional theory. The first-principles calculations reveal that the negative piezoelectric effect of γ-glycine originates from the stretching and compression of glycine molecules induced by hydrogen bonding interactions. The synthetic γ-glycine/PVA films exhibit a piezoelectricity of 10.4 picocoulombs per newton and an ultrahigh piezoelectric voltage coefficient of 324 × 10 −3 volt meters per newton. The biofilms are further developed into flexible, bioresorbable, wireless piezo-ultrasound electrotherapy devices, which are demonstrated to shorten wound healing by ~40% and self-degrade in preclinical wound models. These encouraging results offer reliable approaches for engineering piezoelectric biofilms and developing transient bioelectronics.
multidisciplinary sciences
What problem does this paper attempt to address?
The main problem this paper attempts to address is the development of a flexible, biodegradable ultrasonic wireless piezoelectric device (b-WPUE) to accelerate the wound healing process. Specifically, the paper focuses on the following aspects: 1. **Material Preparation**: The paper proposes an optimized strategy to synthesize highly self-aligned piezoelectric γ-glycine/polyvinyl alcohol (γ-glycine/PVA) films through an ultrasound-assisted process. These films exhibit high piezoelectric performance and can be used to manufacture biodegradable piezoelectric devices. 2. **Enhancement of Piezoelectric Performance**: Existing piezoelectric biomaterials face obstacles in large-scale crystal orientation alignment and weak piezoelectricity. The paper reveals the negative piezoelectric effect of γ-glycine through first-principles calculations and experimentally verifies its piezoelectric performance. The synthesized γ-glycine/PVA films exhibit a piezoelectricity of 10.4 pC/N and an ultra-high piezoelectric voltage coefficient of 324 × 10^-3 Vm/N. 3. **Device Design and Application**: Based on the aforementioned materials, the paper further develops a flexible, bioresorbable wireless ultrasonic piezoelectric device (b-WPUE). This device operates wirelessly under ultrasonic excitation, providing electrical stimulation therapy to accelerate wound healing. Experimental results show that b-WPUE can reduce wound healing time by approximately 40%. 4. **Biocompatibility and Degradability**: The paper also verifies the biocompatibility and biodegradability of b-WPUE, ensuring its safety and effectiveness for in vivo applications. Experiments indicate that the device almost completely degrades within 36 weeks, leaving no harmful residues. In summary, this paper aims to provide new solutions for future medical electronic devices by developing high-performance biodegradable piezoelectric materials and devices, particularly in accelerating wound healing and reducing the need for secondary surgeries.