Surgical Navigation for Malignancies Guided by Near‐Infrared‐II Fluorescence Imaging

Rui‐Qin Yang,Kang‐Liang Lou,Pei‐Yuan Wang,Yi‐Yang Gao,Yong‐Qu Zhang,Min Chen,Wen‐He Huang,Guo‐Jun Zhang
DOI: https://doi.org/10.1002/smtd.202001066
IF: 12.4
2021-01-18
Small Methods
Abstract:<p>Near‐infrared (NIR) fluorescence imaging is an emerging noninvasive imaging modality, with unique advantages in guiding tumor resection surgery, thanks to its high sensitivity and instantaneity. In the past decade, studies on the conventional NIR window (NIR‐I, 750–900 nm) have gradually focused on the second NIR window (NIR‐II, 1000–1700 nm). With its reduced light scattering, photon absorption, and auto‐fluorescence qualities, NIR‐II fluorescence imaging significantly improves penetration depths and signal‐to‐noise ratios in bio‐imaging. Recently, several studies have applied NIR‐II imaging to navigating cancer surgery, including localizing cancers, assessing surgical margins, tracing lymph nodes, and mapping important anatomical structures. These studies have exemplified the significant prospects of this new approach. In this review, several NIR‐II fluorescence agents and some of the complex applications for guiding cancer surgeries are summarized. Future prospects and the challenges of clinical translation are also discussed.</p>
materials science, multidisciplinary,chemistry, physical,nanoscience & nanotechnology
What problem does this paper attempt to address?
This paper aims to solve the problem of precise navigation in cancer surgery. Specifically, traditional imaging techniques such as X - ray, computed tomography (CT), and magnetic resonance imaging (MRI) are difficult to integrate into the operating room, and these instruments cannot reliably provide real - time feedback to surgeons. Although intraoperative ultrasound has been used to guide some cancer surgeries, a single imaging mode is usually not sufficient to distinguish between cancerous and non - cancerous areas. Therefore, it is crucial to develop intraoperative imaging techniques to accurately detect cancerous areas. Near - infrared II (NIR - II, 1000–1700 nm) fluorescence imaging, as an emerging non - invasive imaging method, has unique advantages in guiding tumor resection surgery due to its high sensitivity and immediacy. Compared with the traditional NIR - I window (750–900 nm), NIR - II fluorescence imaging significantly improves the penetration depth and signal - to - noise ratio of biological imaging by reducing light scattering, photon absorption, and tissue autofluorescence. In recent years, NIR - II imaging has been applied to cancer surgery navigation, including locating cancers, evaluating surgical margins, tracking lymph nodes, and mapping important anatomical structures. These studies have shown great promise for this method. In summary, the main problem that this paper attempts to solve is to improve the navigation accuracy in cancer surgery through NIR - II fluorescence imaging technology, thereby reducing the risks of residual tumors and damaging important anatomical structures, and improving surgical outcomes and patient survival rates.