A novel "on-off-on" electrochemiluminescence strategy based on RNA cleavage propelled signal amplification and resonance energy transfer for Pb 2+ detection

Qinghua Gong,Xuejiao Xu,Yanmei Cheng,Xianhong Wang,Dandan Liu,Guangming Nie
DOI: https://doi.org/10.1016/j.aca.2024.342218
IF: 6.911
2024-01-07
Analytica Chimica Acta
Abstract:Background Lead (Pb) is one of the most toxic heavy-metal pollutants. Additionally, lead ions (Pb 2+ ) can accumulate in the human body through the food chain, causing irreversible damage through organ damage and system disorders. In the past few years, the detection of Pb 2+ has mainly relied on instrumental methods such as atomic absorption spectroscopy (AAS) and inductively coupled plasma mass spectrometry (ICP-MS). Nonetheless, these techniques are complicated in terms of equipment and procedures, along with being time-intensive and expensive in terms of detection. These drawbacks have limited their wide application. Hence, there is a pressing need to develop detection techniques for Pb 2+ that are not only cost-efficient but also highly sensitive and specific. Results A novel "on-off-on" electrochemiluminescence (ECL) sensor for detecting Pb 2+ was developed based on the resonance energy transfer (RET) effect between AuNPs and boron nitride quantum dots (BN QDs) and the recognition of Pb 2+ by DNAzyme along with the cleavage reaction of the substrate chain. Poly(6-carboxyindole)/stannic sulfide (P6ICA/SnS 2 ) nanocomposite was employed as a co-reaction accelerator to consequently facilitate the production of intermediate SO 4 •− . This effective enhancement of the reaction led to an improved ECL intensity of BN QDs and enabled the sensor platform to exhibit a higher original ECL response. Benefiting from the combination of the DNAzyme signal amplification strategy with the "on-off-on" design, the ECL sensor showed satisfactory selectivity, good stability, and high sensitivity. This ECL sensor exhibited a linear detection range (LDR) of 10 −12 -10 −5 M and a limit of detection (LOD) of 2.6×10 −13 M. Significance In the present work, an "on-off-on" ECL sensor is constructed based on RET effect for ultrasensitive detection of Pb 2+ . P6ICA/SnS 2 was investigated as the co-reaction accelerator in this sensor. Moreover, this ECL sensor exhibited excellent analytical capability for detecting Pb 2+ in actual water samples, providing a method for detecting other heavy metal ions as well.
chemistry, analytical
What problem does this paper attempt to address?