Energy Storage Capacity Configuration Planning Considering Dual Scenarios of Peak Shaving and Emergency Frequency Regulation

Xiaozheng Chen,Dongliang Nan,Xiaofu Xiong,Hongzhou Chen,Wenqing Ma
DOI: https://doi.org/10.3390/pr12040743
IF: 3.5
2024-04-06
Processes
Abstract:New energy storage methods based on electrochemistry can not only participate in peak shaving of the power grid but also provide inertia and emergency power support. It is necessary to analyze the planning problem of energy storage from multiple application scenarios, such as peak shaving and emergency frequency regulation. This article proposes an energy storage capacity configuration planning method that considers both peak shaving and emergency frequency regulation scenarios. A frequency response model based on emergency frequency regulation combined with low-frequency load shedding is established, taking into account the frequency safety constraints of the system and the principle of idle time reuse, to establish a bi-level programming model. In the upper-level model, the optimization objective is to minimize the annual operating cost of the system during the planning period, combined with the constraints of power grid operation to plan the energy storage capacity. The lower-level model embeds frequency safety constraints with the optimization objective of minimizing the cost of fault losses. To solve the bi-level optimization problem, the Karush–Kuhn–Tucher (KKT) condition and Big-M method were used to transform the bi-level model into a single-layer linear model. Finally, an improved IEEE RTS-24 system was used for numerical verification. The results show that the method proposed in this article can reasonably plan the capacity of energy storage, improve frequency safety during system operation, and reduce the operating cost of the power grid.
engineering, chemical
What problem does this paper attempt to address?
The problem that this paper attempts to solve is how to rationally allocate energy storage capacity in the power system to simultaneously meet the requirements of peak - shaving and emergency frequency regulation. Specifically, the paper focuses on the new electrochemical - based energy storage methods that can not only participate in peak - shaving of the power grid but also provide inertia and emergency power support. Therefore, it is necessary to analyze the energy storage planning problem from multiple application scenarios (such as peak - shaving and emergency frequency regulation). The paper proposes an energy storage capacity allocation planning method considering both peak - shaving and emergency frequency regulation scenarios. By establishing an emergency frequency regulation frequency response model combined with under - frequency load shedding, considering the frequency safety constraints of the system and the principle of idle time reuse, a bi - level programming model is established. The objective of the upper - level model is to minimize the annual operating cost of the system during the planning period and plan the energy storage capacity in combination with the power grid operation constraints; the lower - level model embeds frequency safety constraints, and the optimization objective is to minimize the fault loss cost. To solve the bi - level optimization problem, the Karush - Kuhn - Tucker (KKT) conditions and the Big - M method are used to convert the bi - level model into a single - level linear model. Finally, numerical verification is carried out through the improved IEEE RTS - 24 system, and the results show that the method proposed in this paper can rationally plan the energy storage capacity, improve the frequency security of system operation, and reduce the operating cost of the power grid.