A multi-channel electrochemical biosensor based on polyadenine tetrahedra for the detection of multiple drug resistance genes

Yanan Song,Jun Feng,Xueming Wang,Yanli Wen,Li Xu,Yinbo Huo,Lele Wang,Zhenzhou Yang,Qing Tao,Gang Liu,Min Chen,Lanying Li,Juan Yan
DOI: https://doi.org/10.1039/d4an00488d
2024-04-30
The Analyst
Abstract:Antimicrobial resistance poses a serious threat to human health due to the high morbidity and mortality caused by drug-resistant gene infections. Therefore, the development of rapid, sensitive and selective identification methods is the key to improve the survival rate of patients. In this paper, a sandwich-type electrochemical DNA biosensor based on polyadenine-DNA tetrahedron probe was constructed. The key experimental conditions were optimized, including the length of polyadenine, the concentration of polyadenine DNA tetrahedron, the concentration of signal probe and hybridization time. At the same time, poly-Avidin-HRP80 was used to enhance the electrochemical detection signal. Finally, excellent biosensor performance was achieved, and the detection limit of synthetic DNA target was as low as 1 fM. In addition, we verified the practicability of the system by analyzing E. coli with MCR-1 plasmid, and realized multi-channel detection of drug resistance genes MCR-1, blaNDM, blaKPC and blaOXA. Under the ideal electrochemical interface, the polyA-based biosensor exhibits excellent stability, which provides a powerful technical support for the rapid detection of antibiotic-resistant strains in the field.
chemistry, analytical
What problem does this paper attempt to address?