Analysis of Minimal Channel Electroencephalography for Wearable Brain–Computer Interface

Arpa Suwannarat,Setha Pan-ngum,Pasin Israsena
DOI: https://doi.org/10.3390/electronics13030565
IF: 2.9
2024-01-31
Electronics
Abstract:Electroencephalography (EEG)-based brain—computer interface (BCI) is a non-invasive technology with potential in various healthcare applications, including stroke rehabilitation and neuro-feedback training. These applications typically require multi-channel EEG. However, setting up a multi-channel EEG headset is time-consuming, potentially resulting in patient reluctance to use the system despite its potential benefits. Therefore, we investigated the appropriate number of electrodes required for a successful BCI application in wearable devices using various numbers of EEG channels. EEG multi-frequency features were extracted using the "filter bank" feature extraction technique. A support vector machine (SVM) was used to classify a left/right-hand opening/closing motor imagery (MI) task. Nine electrodes around the center of the scalp (F3, Fz, F4, C3, Cz, C4, P3, Pz, and P4) provided high classification accuracy with a moderate setup time; hence, this system was selected as the minimal number of required channels. Spherical spline interpolation (SSI) was also applied to investigate the feasibility of generating EEG signals from limited channels on an EEG headset. We found classification accuracies of interpolated groups only, and combined interpolated and collected groups were significantly lower than the measured groups. The results indicate that SSI may not provide additional EEG data to improve classification accuracy of the collected minimal channels. The conclusion is that other techniques could be explored or a sufficient number of EEG channels must be collected without relying on generated data. Our proposed method, which uses a filter bank feature, session-dependent training, and the exploration of many groups of EEG channels, offers the possibility of developing a successful BCI application using minimal channels on an EEG device.
engineering, electrical & electronic,computer science, information systems,physics, applied
What problem does this paper attempt to address?
The main problem that this paper attempts to solve is: **How to implement an efficient and user - friendly system in wearable brain - computer interfaces (BCI) with the minimum number of EEG channels**. Specifically, the researchers focused on: 1. **Reducing the number of EEG electrodes**: Traditional multi - channel EEG setups require a long preparation time and may lead to patients being reluctant to use these devices. Therefore, the researchers hope to find a solution that can maintain high classification accuracy while significantly reducing the number of required electrodes. 2. **Improving the user - friendliness of the system**: By reducing the number of electrodes, the preparation time of the device can be shortened, thereby increasing user acceptance and comfort, especially in long - term use scenarios such as rehabilitation training. 3. **Evaluating the effectiveness of interpolation techniques**: The researchers also explored whether additional data can be generated from a limited number of EEG channels through interpolation techniques (such as spherical spline interpolation SSI) to improve classification accuracy. However, the results showed that the interpolation technique did not significantly improve the classification performance. ### Overview of research methods To achieve the above goals, the researchers carried out the following tasks: - **Feature extraction**: Use the "Filter Bank" (FB) technique to extract multi - band features. - **Classification algorithm**: Adopt the Support Vector Machine (SVM) to classify left - and right - hand opening and closing motor imagery tasks. - **Electrode selection**: Select nine electrodes near the scalp center (F3, Fz, F4, C3, Cz, C4, P3, Pz, and P4), which can provide high classification accuracy and a moderate setup time. - **Interpolation technique evaluation**: Apply spherical spline interpolation (SSI) to evaluate its effectiveness in reducing the number of electrodes. ### Main conclusions The study found that using nine electrodes can significantly reduce the number of electrodes while maintaining high classification accuracy, thereby improving the user - friendliness of the system. However, the interpolation technique failed to effectively improve the classification performance, indicating that in practical applications, it is still necessary to rely on actually collected data rather than generated data to improve classification accuracy. In general, this study provides valuable insights for the development of wearable BCI systems based on a small number of EEG channels, which is helpful for promoting the practical application of BCI technology in medical rehabilitation and other fields.