Universally Quantitative Band-Selective Pure Shift NMR Spectroscopy

Howard M Foster,Mathias Nilsson,Ralph W Adams,Gareth A Morris
DOI: https://doi.org/10.1021/acs.analchem.4c01199
IF: 7.4
2024-05-31
Analytical Chemistry
Abstract:NMR spectroscopy is often described as a quantitative analytical technique. Strictly, only the simple pulse-acquire experiment is universally quantitative, but the poor signal resolution of the 1H NMR pulse-acquie experiment frequently complicates quantitative analysis. Pure shift NMR techniques provide higher resolution, by reducing signal overlap, but they are susceptible to a variety of sources of site-dependent signal loss. Here, we introduce a new method that corrects for signal loss from...
chemistry, analytical
What problem does this paper attempt to address?
### Problems Addressed by the Paper The paper aims to address the issue of quantitative analysis in Nuclear Magnetic Resonance (NMR) spectroscopy. Specifically, while traditional NMR spectroscopy is often described as a quantitative analysis technique, only simple pulse-acquire experiments are strictly quantitative in all cases. However, due to the poor resolution of 1H NMR pulse-acquire experiment signals, quantitative analysis is often complicated. PureShift NMR technology improves resolution by reducing signal overlap, but these techniques are susceptible to site-dependent signal loss from various sources, hindering their application in quantitative analysis. ### Solution To overcome these issues, the authors introduce a new method called **Universally Quantitative Band-Selective PureShift NMR Spectroscopy**, abbreviated as **EXQUISITE**. This method corrects these signal losses by performing different numbers of iterations of the same pulse sequence elements before data acquisition, allowing extrapolation back to lossless signals. Specifically: 1. **Signal Loss Correction**: By iterating the same pulse sequence elements multiple times, site-dependent attenuation of different signals can be measured and corrected. 2. **Applicable Modes**: This method is applicable to both interferogram and semi-realtime acquisition modes. 3. **High Precision**: For a mixture containing 3 components, the integral values obtained by this method differ by less than 1% from those obtained by pulse-acquire experiments. ### Experimental Validation To validate the effectiveness of this method, the authors conducted the following experiments: 1. **Water Model System**: By varying the amplitude of the pulsed field gradient (PFG) and adding extra delays in the sequence, the water signal was attenuated to different extents in different experiments due to relaxation, diffusion, and convection. The results showed that using the EXQUISITE method significantly improved quantitative performance, with the integral deviation of traditional experiments being about 13%, while after two to three iterations of extrapolation, the deviation was reduced to below 0.5%. 2. **Mixture of Ibuprofen, Diethyl Ether, and Ethyl Isovalerate**: In semi-realtime and interferogram modes, the selected multiplet signals in the mixture of Ibuprofen (I), Diethyl Ether (D), and Ethyl Isovalerate (E) were quantitatively analyzed. The results showed that the EXQUISITE method also performed excellently in these complex mixtures, accurately determining the proportions of each component. ### Conclusion The method proposed in this paper successfully addresses the signal loss issue in PureShift NMR technology for quantitative analysis, making NMR spectroscopy more reliable and accurate for the quantitative analysis of complex molecules and mixtures.