Abstract:Under the condition of the shield tunnel intersecting the ground fissure section at a right angle, a physical model test was conducted at a geometric scale ratio of 1:30. This test aimed to compare and analyze the force and deformation of the conventional shield tunnel and shield tunnel after adopting measures to mitigate the effects of ground fissure dislocation. Meanwhile, a finite-element numerical simulation of a conventional shield tunnel under the same working conditions was performed. The physical model test results align closely with the outcomes predicted by numerical calculations. The deformation observed in the shield tunnel primarily consisted of vertical shear deformation near the ground fissure, accompanied by a minor torsional deformation. In grade IV ground fissure sites, both the conventional shield tunnel and shield tunnel with mortise-groove cross-section after taking measures exhibit a basic level of safety. However, only the shield tunnel, after taking measures, is safe when the ground fissure develops to grade III. By contrast, the conventional shield tunnel generates significant shear deformation at the first circumferential seam in the footwall of the ground fissure, which easily causes the joints inside the circumferential seam to yield shear. When the ground fissure grade was raised to II, the conventional shield tunnel and shield tunnel with mortise-groove cross-section after taking measures experienced relatively serious damage.
construction & building technology
What problem does this paper attempt to address?
Your answer: The paper primarily investigates the comparative study of the mechanical properties of shield tunnels in ground fissure zones. Specifically, the paper aims to address the following issues: 1. **Comparative Analysis**: The paper conducts a comparative analysis of the stress and deformation conditions of conventional shield tunnels versus those with mortise-section shield tunnels in ground fissure zones through physical model experiments. 2. **Effectiveness Assessment of Measures**: It assesses the safety of shield tunnels in ground fissure zones after implementing measures, especially the performance of shield tunnels under different levels of ground fissures (Level IV, III, II, I). 3. **Basis for Structural Design**: The paper provides experimental evidence for the structural design of shield tunnels in subway lines crossing ground fissures and offers references for prevention and control measures in ground fissure zones. 4. **Numerical Simulation Validation**: A three-dimensional finite element model is established, and its numerical calculation results are used to verify the accuracy of the physical model experiments. Through these studies, the paper aims to provide scientific guidance for ensuring the safety and stability of shield tunnels during subway construction in active ground fissure areas, particularly in cities like Xi'an where ground fissures occur frequently. The research not only focuses on the mechanical response of the tunnels themselves but also considers the effectiveness of prevention and control measures, which is of significant importance for enhancing the safety level of urban infrastructure construction and operation.