Force Tracking Control Method for Robotic Ultrasound Scanning System under Soft Uncertain Environment

Jinlei Jiang,Jingjing Luo,Hongbo Wang,Xiuhong Tang,Fan Nian,Lizhe Qi
DOI: https://doi.org/10.3390/act13020062
IF: 2.6
2024-02-07
Actuators
Abstract:Robotic ultrasound scanning has excellent potential to reduce physician workload, obtain higher-quality imaging, and reduce costs. However, the traditional admittance control strategy for robotics cannot meet the high-precision force control requirements for robots, which are critical for improving image quality and ensuring patient safety. In this study, an integral adaptive admittance control strategy is proposed for contact force control between an ultrasound probe and human skin to enhance the accuracy of force tracking. First, a robotic ultrasound scanning system is proposed, and the system's overall workflow is introduced. Second, an adaptive admittance control strategy is designed to estimate the uncertain environmental information online, and the estimated parameters are used to modify the reference trajectory. On the basis of ensuring the stability of the system, an integral controller is then introduced to improve the steady-state response. Subsequently, the stability of the proposed strategy is analysed. In addition, a gravity compensation process is proposed to obtain the actual contact force. Finally, through a simulation analysis, the effectiveness of the strategy is discussed. Simultaneously, a series of experiments are carried out on the robotic ultrasound scanning system, and the results show that the strategy can successfully maintain a constant contact force under soft uncertain environments, which effectively improves the efficiency of scanning.
engineering, mechanical,instruments & instrumentation
What problem does this paper attempt to address?
### Problems the Paper Aims to Solve This paper aims to address the issue of force tracking control in robotic ultrasound scanning. Specifically, its main objectives include: 1. **Constructing a Robotic Ultrasound System**: - Proposing a robotic ultrasound scanning system and obtaining the scanning trajectory through visual methods. - Acquiring the actual contact force using gravity compensation techniques. 2. **Proposing an Integral Adaptive Impedance Control Strategy (IAAC)**: - Addressing the issues of force tracking accuracy and force overshoot in existing impedance control strategies by proposing a new integral adaptive impedance control strategy. - This strategy effectively avoids force overshoot and maintains stable contact force during the scanning process. 3. **Experimental Validation**: - Conducting comparative studies between the proposed IAAC strategy and traditional impedance control methods. - Experimental results show that the IAAC strategy meets the requirements of soft uncertain environments (such as ultrasound scanning) and its adaptability is significantly better than traditional impedance controllers. In summary, the core purpose of this paper is to improve the quality of ultrasound scanning by enhancing the force tracking control algorithm, thereby providing a better interactive experience for patients.