Multisite studies for optimization of a highly efficient culture assay used for in vitro detection of residual undifferentiated human pluripotent stem cells intermingled in cell therapy products

Takeshi Watanabe,Satoshi Yasuda,Shinji Kusakawa,Takuya Kuroda,Hatsue Furukawa,Mayumi Futamura,Shigekazu Shimizu,Akihiko Morishita,Shinko Hata,Akiko Koeda,Kana Komatsu,Yoji Sato
DOI: https://doi.org/10.1016/j.reth.2024.06.007
IF: 3.651
2024-06-24
Regenerative Therapy
Abstract:Highlights • Colony formation and sorting efficiencies evaluated in MEASURE2 multisite studies. • CEPT combination treatment improved colony formation efficiency of hPSCs. • Achieved >80% sorting efficiency when using anti-Tra-1-60-conjugated microbeads. Introduction MEASURE2 (Multisite Evaluation Study on Analytical Methods for Non-clinical Safety Assessment of HUman-derived REgenerative Medical Products 2) is a Japanese experimental public–private partnership initiative that aims to standardize testing methods for tumorigenicity evaluation of human pluripotent stem cell (hPSC)-derived cell therapy products (CTPs). MEASURE2 organized multisite studies to optimize the methodology of the highly efficient culture (HEC) assay, a sensitive culture-based in vitro assay for detecting residual undifferentiated hPSCs in CTPs. Methods In these multisite studies, 1) the efficiency of colony formation by human induced pluripotent stem cells (hiPSCs) under two different culture conditions and 2) the sorting efficiency of microbeads conjugated to various anti-hPSC markers during hiPSC enrichment were evaluated using samples in which hiPSCs were spiked into hiPSC-derived mesenchymal stem cells. Results The efficiency of colony formation was significantly higher under culture conditions with the combination of Chroman 1, Emricasan, Polyamines, and Trans-ISRIB (CEPT) than with Y-27632, which is widely used for the survival of hPSCs. Between-laboratory variance was also smaller under the condition with CEPT than with Y-27632. The sorting efficiency of microbeads conjugated with the anti-Tra-1-60 antibody was sufficiently higher (>80%) than those of the other various microbeads investigated. Conclusions Results of these multisite studies are expected to contribute to improvements in the sensitivity and robustness of the HEC assay, as well as to the future standardization of the tumorigenicity risk assessment of hPSC-derived CTPs.
engineering, biomedical,cell & tissue engineering
What problem does this paper attempt to address?