Association of atrial mechanical dispersion with atrial fibrillation recurrence following catheter ablation: results of the ASTRA-AF pilot study

Dorit Knappe,Julia Vogler,Jessica Weimann,Victor Banas,Sevenai Yildirim,Felix Memenga,Juliana Senftinger,Laura Keil,Djemail Ismaili,Moritz Nies,Andreas Rillig,Stephan Willems,Stefan Blankenberg,Paulus Kirchhof,Andreas Metzner,Christoph Sinning
DOI: https://doi.org/10.1007/s00392-024-02435-0
IF: 6.138
2024-05-22
Clinical Research in Cardiology
Abstract:Aims For patients with symptomatic drug-refractory atrial fibrillation (AF), catheter ablation to achieve rhythm control is an important therapeutic option. The atrial mechanical dispersion measured as standard deviation of the time to peak strain (SD-TPS) is associated with the risk of AF recurrence following catheter ablation. Methods The study cohort prospectively enrolled n = 132 consecutive patients with paroxysmal ( n = 88) or persistent AF ( n = 44) presenting for de novo pulmonary vein isolation (PVI) and followed for 1 year. We related left atrial (LA) volume, LA ejection fraction, SD-TPS, and global longitudinal strain of the left ventricle and clinical variables (sex, age, and type of AF) to AF recurrence. Results Kaplan–Meier curves showed higher AF recurrence rate with an increase of SD-TPS with the calculated cut-off of 38.6 ms. Uni- and multivariable Cox regression analysis could show that SD-TPS had the highest relevance regarding AF recurrence with a HR of 1.05 (95% CI, 1.01; 1.09, p = 0.01) and HR of 1.05 (95% CI, 1.01; 1.09, p = 0.02) per 10 ms increase. In the additional analyses for the model including the clinical variables age, sex, and type of AF with paroxysmal or persisting AF, SD-TPS did only show a trend and after adjusting for covariates, SD-TPS showed a HR of 1.04 (95% CI, 0.99; 1.09, p = 0.09) per 10 ms increase. Conclusion Atrial mechanical dispersion was associated with recurrent AF. Graphical
cardiac & cardiovascular systems
What problem does this paper attempt to address?
This paper aims to explore the relationship between atrial mechanical dispersion (measured by standard deviation time - to - peak strain (SD - TPS)) and recurrence after atrial fibrillation (AF) ablation. Specifically, the research objectives include: 1. **Evaluating the association between SD - TPS and AF recurrence**: Researchers hope to determine through the analysis of SD - TPS whether it can be used as a risk indicator for predicting AF recurrence. 2. **Evaluating the combined influence of SD - TPS with other imaging variables and clinical factors**: In addition to SD - TPS, the study also considered other imaging variables (such as left atrial volume index (LAVI), left ventricular global longitudinal strain (LV - GLS), etc.) and clinical variables (such as gender, age, AF type, etc.) to comprehensively assess the impact of these factors on AF recurrence. ### Research background Atrial fibrillation (AF) is one of the most common arrhythmias, especially in the elderly. When drug treatment is difficult to control symptoms, catheter ablation has become an important treatment option. However, although catheter ablation is more effective in maintaining sinus rhythm than drug treatment, there is still a high recurrence rate of AF. Therefore, finding reliable predictors is crucial for optimizing treatment decisions and improving success rates. ### Research methods - **Research subjects**: The study included 132 AF patients who underwent pulmonary vein isolation (PVI) for the first time, among which 88 were paroxysmal AF and 44 were persistent AF. - **Data collection**: All patients underwent transthoracic and transesophageal echocardiography before surgery. The main imaging parameters included LAVI, left ventricular ejection fraction (LVEF), left atrial ejection fraction (LAEF), LV - GLS and SD - TPS. - **Follow - up**: Patients were followed up within 1 year after surgery, and AF recurrence was evaluated by 24 - hour Holter ECG. ### Main findings - **Relationship between SD - TPS and AF recurrence**: Kaplan - Meier curves showed that an increase in SD - TPS was associated with an increase in AF recurrence rate, and the calculated critical value was 38.6 ms. Univariate and multivariate Cox regression analyses showed that for every 10 - ms increase in SD - TPS, the risk of AF recurrence increased by 5% (HR = 1.05, 95% CI: 1.01 - 1.09, p = 0.01). - **Influence of other variables**: In multivariate analysis, age was the only clinical variable that significantly predicted AF recurrence (HR = 1.06, 95% CI: 1.02 - 1.11, p = 0.002), while SD - TPS only showed a trend (HR = 1.04, 95% CI: 1.00 - 1.10, p = 0.07). - **Relationship between LAVI and AF recurrence**: LAVI did not show a significant association with AF recurrence. ### Conclusion Atrial mechanical dispersion (SD - TPS) is related to recurrence after AF ablation and may be a valuable predictor. However, the research results need to be further verified in a larger cohort. In addition, a comprehensive evaluation method combining imaging and clinical variables is helpful for more accurately predicting the risk of AF recurrence.