Energy, exergy, and economic analysis of a novel solar-assisted ejector subcooling CO 2 transcritical refrigeration systemt

Tailan Yin,Qichao Yang,Jiawei Jiang,Zeye Zheng,Yuanyang Zhao,Guangbin Liu,Liansheng Li
DOI: https://doi.org/10.1016/j.solener.2024.113080
IF: 7.188
2024-11-10
Solar Energy
Abstract:To further enhance the performance of transcritical CO 2 refrigeration cycle (base cycle), a solar-assisted ejector subcooling transcritical CO 2 refrigeration cycle (SESRS) is proposed. The base cycle is subcooled utilizing a solar-assisted ejector refrigeration cycle. This research performed energy, exergy, and economic evaluations of SESRS utilizing the eco-friendly refrigerant R152a in the ejector cycle based on the established model. The thermodynamic analysis results demonstrate that SESRS outperform the base cycle. At typical working conditions, the COP m of the SESRS demonstrates a 22.96 % increase compared to that of the base cycle. Although the total cost of the SESRS is 7.98 %–17.9 % higher than that of the base cycle when subcooling degree is 5 °C, the enhancement of COP m is larger and is increased by approximately 18.34 %–26.22 %. The impact of subcooling degree and other parameters on system performance are also investigated. Overall, this study confirms the potential of the SESRS system for utilization in the refrigeration and air-conditioning fields. Considering both the system's performance and economy, further optimized analysis should be done on key operational parameters, such as subcooling degree and discharge pressure.
energy & fuels
What problem does this paper attempt to address?