Developing a new radiomics-based CT image marker to detect lymph node metastasis among cervical cancer patients

Xuxin Chen,Wei Liu,Theresa C Thai,Tara Castellano,Camille C Gunderson,Kathleen Moore,Robert S Mannel,Hong Liu,Bin Zheng,Yuchen Qiu,Theresa C. Thai,Camille C. Gunderson,Robert S. Mannel
DOI: https://doi.org/10.1016/j.cmpb.2020.105759
IF: 6.1
2020-12-01
Computer Methods and Programs in Biomedicine
Abstract:<h3 class="u-h4 u-margin-m-top u-margin-xs-bottom">Background and Objective</h3><p>In diagnosis of cervical cancer patients, lymph node (LN) metastasis is a highly important indicator for the following treatment management. Although CT/PET (i.e., computed tomography/positron emission tomography) examination is the most effective approach for this detection, it is limited by the high cost and low accessibility, especially for the rural areas in the U.S.A. or other developing countries. To address this challenge, this investigation aims to develop and test a novel radiomics-based CT image marker to detect lymph node metastasis for cervical cancer patients.</p><h3 class="u-h4 u-margin-m-top u-margin-xs-bottom">Methods</h3><p>A total of 1,763 radiomics features were first computed from the segmented primary cervical tumor depicted on one CT image with the maximal tumor region. Next, a principal component analysis algorithm was applied on the initial feature pool to determine an optimal feature cluster. Then, based on this optimal cluster, the prediction models (i.e., logistic regression or support vector machine) were trained and optimized to generate an image marker to detect LN metastasis. In this study, a retrospective dataset containing 127 cervical cancer patients were established to build and test the model. The model was trained using a leave-one-case-out (LOCO) cross-validation strategy and image marker performance was evaluated using the area under receiver operation characteristic (ROC) curve (AUC).</p><h3 class="u-h4 u-margin-m-top u-margin-xs-bottom">Results</h3><p>The results indicate that the SVM based imaging marker achieved an AUC value of 0.841 ± 0.035. When setting an operating threshold of 0.5 on model-generated prediction scores, the imaging marker yielded a positive and negative predictive value (PPV and NPV) of 0.762 and 0.765 respectively, while the total accuracy is 76.4%.</p><h3 class="u-h4 u-margin-m-top u-margin-xs-bottom">Conclusions</h3><p>This study initially verified the feasibility of utilizing CT image and radiomics technology to develop a low-cost image marker to detect LN metastasis for assisting stratification of cervical cancer patients.</p>
engineering, biomedical,computer science, interdisciplinary applications,medical informatics, theory & methods
What problem does this paper attempt to address?