Interictal HFO and FDG‐PET correlation predicts surgical outcome following SEEG

Baotian Zhao,Aileen McGonigal,Wenhan Hu,Chao Zhang,Xiu Wang,Jiajie Mo,Xiaobin Zhao,Lin Ai,Xiaoqiu Shao,Kai Zhang,Jianguo Zhang
DOI: https://doi.org/10.1111/epi.17485
IF: 6.74
2022-12-15
Epilepsia
Abstract:Objective This study aimed to investigate the quantitative relationship between interictal 18F‐fluorodeoxyglucose positron emission tomography (FDG‐PET) and interictal high frequency oscillations (HFOs) from stereoelectroencephalography (SEEG) recordings in refractory epilepsy patients. Methods We retrospectively included 32 patients. FDG‐PET data were quantified through statistical parametric mapping (SPM) t‐test modeling with normal controls. Interictal SEEG segments with four 10‐min segments were randomly selected. HFO detection and classification procedures were automatically performed. Channel‐based HFOs separating ripple (80‐250Hz) and fast ripple (FR, 250‐500Hz) counts were correlated with the surrounding metabolism T score at individual and group level respectively. The association was further validated across anatomical seizure origins and sleep versus wake states. We built a joint feature FR×T reflecting the FR and hypometabolism concordance to predict surgical outcome in 28 patients who underwent surgery. Results We found a negative correlation between interictal FDG‐PET and HFOs through the linear mixed effect model (R2 = 0.346 and 0.457 for ripple and FR, respectively, p
clinical neurology
What problem does this paper attempt to address?