Abstract:This letter studies the mechanism of a type of forced power system oscillation induced by imperfect nonlinearity compensation with a steam-turbine governing system. The nonlinear valve control characteristic of a steam turbine is usually compensated by its inverse characteristic performed by its governor for an overall linear characteristic of the governing system. In reality, a governing system may remain nonlinear due to imperfect compensation, which can result in a limit cycle forcing the generator and even an extensive neighboring area of the power grid to oscillate at a low frequency. A compensation imperfection index is proposed to evaluate the residual nonlinearity and discover how a limit cycle can occur and cause forced oscillation of a steam-turbine generator. Time-domain simulation on a real forced oscillation event caused by a steam-turbine governor validates the finding of the paper and supports the fact that opening the governor control loop of the oscillation-source generator can effectively eliminate this type of forced oscillation.
energy & fuels,engineering, electrical & electronic
What problem does this paper attempt to address?
This paper attempts to solve the problem of power system forced oscillations caused by steam turbine governors. Specifically, the paper investigates a mechanism of power system forced oscillations due to incomplete compensation of nonlinear valve characteristics by the governor. This incomplete compensation may lead to limit cycles, which in turn force generators and even wide areas of the power grid to generate low - frequency oscillations. To evaluate the impact of this incomplete compensation, the paper proposes a Compensation Imperfection Index (CII) to quantify the remaining nonlinearity and explore how limit cycles are formed and lead to forced oscillations. The findings of the paper are verified by time - domain simulations of actual cases, showing that when oscillations occur, disconnecting the governor control loop of the oscillating - source generator can effectively eliminate this type of forced oscillation. The paper also discusses methods of temporarily dealing with oscillations by manually controlling the governor, and proposes reducing the remaining nonlinearity of the governor system by carefully setting the inverse characteristics of valve flow to prevent the occurrence of such oscillations. CII is a very useful index that can guide the setting of the inverse characteristics of valve flow.