Abstract:Background and purpose: Concerns have emerged regarding elevated levels of cobalt and chromium in patients with metal-on-metal megaprostheses. This prospective study aims to identify systemic cobalt and chromium levels in metal-on-polyethylene knee and hip megaprostheses and their associations with other factors.Methods: 56 patients underwent knee or hip megaprosthesis surgery at 2 sarcoma centers. Serum cobalt and chromium levels were measured preoperatively and thrice within the first year using inductively coupled plasma mass spectrometry.Results: A statistically significant difference in serum cobalt levels (1.4 ppb; 95% confidence interval [CI] 0.0–3.3) was observed 1 year after knee megaprosthesis surgery compared with preoperative levels. In contrast no difference in chromium levels was observed after 1 year compared with preoperative levels (0.05 ppb; CI 0.0–0.8). An association between younger age, higher eGFR, and increased cobalt levels was observed. No significant correlations were found between ion levels and resection length or the number of modular connections.Conclusion: We found elevated serum ion levels in metal-on-polyethylene knee megaprostheses in contrast to metal-on-polyethylene hip megaprostheses. Furthermore, a positive correlation between cobalt and chromium levels, and between cobalt and eGFR was identified, along with a negative correlation between cobalt and age. This study highlights the importance of monitoring systemic cobalt and chromium levels in patients with megaprostheses.
orthopedics
What problem does this paper attempt to address?