Characterization of Indoor Air Quality in a University Library: Implications Associated with Pollutant Emissions from New and Old Books and Chemicals

Thairine Lima dos Santos,Márcia Nogueira da Silva de la Cruz,Adriana Gioda,Celeste Yara dos Santos Siqueira
DOI: https://doi.org/10.1080/15275922.2024.2432495
2024-11-30
Environmental Forensics
Abstract:During a 1-year study, organic aerosol indoor air samples were collected from sites in a library in Rio de Janeiro, Brazil. Indoor air is a cause for public concern in Brazil. This study presents an indoor air survey wherein the concentrations of aliphatic hydrocarbons, phthalates, phenyl phosphates, aldehydes, limonene, organic acids, and particulate matter were determined. Acids were estimated to be ranging between 0.01 and 30.26 ng m −3 , whereas furfural ranged between 0.5 and 3.6 g m −3 . Compounds such as furfural, hexanal, benzaldehyde, and vanillin were only detected indoors. Results showed that total suspended particle concentrations were higher outdoors than indoors. Interestingly, 1, 1, 1-trichloro-2, 2-bischlorophenylethane (DDT), and its derivatives were also present. Pesticides are used in libraries to control paper-degrading pests. Therefore, DDT and other chemicals remain nondegraded and pollute the library rooms. This study demonstrates the relevance of monitoring indoor air quality in libraries and the pollutants that can affect the well-being of occupants. Moreover, indoor air quality monitoring can provide early warning to library managers about the effects of indoor air characteristics on unprotected and/or preserved items.
environmental sciences
What problem does this paper attempt to address?