Marlex Mesh Reconstruction of the Extensor Mechanism

Matthew P. Abdel,Christopher N. Carender,Nicholas A. Bedard,Kevin I. Perry,Mark W. Pagnano,Arlen D. Hanssen
DOI: https://doi.org/10.2106/jbjs.23.01006
2024-01-09
Journal of Bone and Joint Surgery
Abstract:Marlex mesh reconstruction of the extensor mechanism following total knee arthroplasty (TKA) has demonstrated excellent early results. The purpose of the present study was to evaluate longer-term results of Marlex mesh reconstruction of the extensor mechanism in 93 TKAs. Seventy-seven reconstructions were aseptic, and 16 were performed as part of a 2-stage exchange for the treatment of infection. Mean follow-up was 8 years. Twenty-eighty patients experienced mesh failure. Seventeen failures were treated with mesh revision (8 for patellar tendon rupture, 7 for quadriceps tendon rupture, and 2 for symptomatic lengthening). The 10-year cumulative incidence of mesh revision for mesh failure was 20%. Extensor lag improved by a mean of 28°, with a mean extensor lag of 9° at most recent follow-up. At a mean follow-up of 8 years, Marlex mesh reconstruction was a durable and reliable technique to treat both aseptic and septic ruptures of the extensor mechanism. Level of Evidence: Therapeutic Level IV . See Instructions for Authors for a complete description of levels of evidence.
surgery,orthopedics
What problem does this paper attempt to address?