Artificial ground reflector size and position effects on energy yield and economics of single‐axis‐tracked bifacial photovoltaics

Mandy R. Lewis,Silvana Ovaitt,Byron McDanold,Chris Deline,Karin Hinzer
DOI: https://doi.org/10.1002/pip.3811
2024-05-09
Progress in Photovoltaics Research and Applications
Abstract:Artificial ground reflectors were studied through modeling and field experiments for bifacial single‐axis‐tracked photovoltaic systems. Fielded reflectors increased daily energy yield up to 6.2%. Modeled reflectors increased irradiance by 1.9–8.6% and energy yield by 0.9–4.5% annually after considering clipping. Calculated maximum viable reflector costs were ‐ 2.50–4.60/m2, including both material and installation, in Golden. We expanded our analysis to cover a latitude range of 32–48°N and demonstrated that higher‐latitude installations with lower energy yield and higher diffuse irradiance content can support higher reflector costs. In both modeling and field tests, and for all locations, the ideal placement of the reflectors was found to be directly underneath the module due to the optimized rear irradiance increase.
materials science, multidisciplinary,physics, applied,energy & fuels
What problem does this paper attempt to address?