Detection of Myocardial Infarction with Dual Energy CT Myocardial Iodine Maps and Perfusion Myocardial Single Photon Emission Computed Tomography Scintigraphy: an Experimental Study in Canine
PENG Jin,ZHANG Long-jiang,ZHU Fei-peng,CHEN Si-min,LUO Song,JI Heng-shan,ZHOU Chang-sheng,ZHU Hong,LU Guang-ming
DOI: https://doi.org/10.3760/cma.j.issn.1005-1201.2011.02.008
2011-01-01
Abstract:Objective To investigate the feasibility and accuracy of dual energy CT myocardial iodine maps in detecting acute myocardial infarction in canine model. Methods Myocardial ischemia model was made by ligaturing left anterior descending coronary arteries (LAD) after thoracotomy in six dogs, while another 3 dogs undergoing thoracotomy not ligaturing LAD as control group. Before and three hours after operation, dual-source CT (DSCT) was performed, followed by resting 99Tcm-MIBI single photon emission computed tomography myocardial perfusion imaging. Then, dogs were sacrificed, and the hearts were removed, triphenyltetrazolium chloride staining and conventional HE staining were performed. CT number of non-ischemic and ischemic regions were measured and analyzed. The wall of the left ventricle in the short axis was divided into 17 segments, the segments of myocardial perfusion defect in DSCT myocardial iodine maps, SPECT, and pathology were determined. Student t test was used to analyze the difference of CT number between infarcted and non-infarcted myocardium. Kappa test was used for the accuracy of DSCT myocardial iodine maps and SPECT in detecting myocardial ischemia according to the pathological results. Results No abnormal regions were detected using DSCT myocardial iodine maps in preoperative control and infarction group. After thoracotomy, partial sparse or defective perfusion was consistently noted in six dogs' apical anterior and partition wall in both DSCT myocardial iodine maps and SPECT. In the infarcted group, the attenuation of infarction region (34.75 ± 16.66) HU was significantly decreased compared with preoperative measurements ( 123. 18 ± 15.38 ) HU ( t = 10. 526, P < 0. 01 ); decreased perfusion in the infarcted region was also noted in the DSCT myocardial iodine maps and SPECT. The sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of DSCT myocardial iodine maps and SPECT were 85.0% (34/40) , 84. 1% (95/113) ,65.4% (34/52) ,94. 0%(95/101) ,and 82. 5% (33/40), 90. 3% ( 102/113 ) ,75.0% (33/44) ,93.6% ( 102/109 ), respectively.Kappa values were 0. 63 and 0. 71 for the agreement of DSCT myocardial iodine maps and SPECT.Conclusion DSCT myocardial iodine maps is comparable diagnostic accuracy with rest SPECT myocardial perfusion imaging in detection of acute myocardial infarction in a canine model.