A REVIEW ON CORE SHELL TECHNOLOGY IN HIGH PERFORMANCE LIQUID CHROMATOGRAPHY: DRUG ANALYSIS

Leela Bhaskar,Sunand Kumar,K. Sheela,Vasubabu,Sri Pavan Kumar Ch
Abstract:C olumn is the heart of the chromatographic systems. Now a days in order to increase the separation efficiency a new technology of column packed with core shell particles was used in HPLC .The core shell particles revolutionized the chromatography industry by providing faster methods without sacrificing resolution .this specialized particles provides higher efficiency and through put which leads to a reduction in solvent consumption. The literature here by describe the performance difference between the core shell particles column and traditional HPLC columns and the results shows that core shell columns are a promising toll in drug analysis. . the with Halo C18, it was reported that Kinetex C18 resulted in better performance with no loss in peak capacity with increasing velocity [23] . It was believed that C term in the HETP plot for the Halo particles was significantly larger, which contradicted with the reduced diffusion distance when using reduced velocities. Another study indicated that this increase in performance could be a result of the difference in particles size between the Kinetex (2.6m) and Halo (2.7m) [22] . The result confirmed the very flat HETP curve, the very low C term of the Kinetex column and its ability to successfully operate at high flow rates while experiencing less efficiency loss than other columns [22] . A systematic evaluation was carried out by Oláh et al. to compare the kinetic performance on Kinetex and Ascentis Express (Sigma–Aldrich) columns by constructing the van Deemter, Knoxand Kinetic plots using test mixture of estradiol, levonorgestrel, bicalutamide, and ivermectin [24] . These results indicated that the Kinetex column offered faster mass transfer with a flatter C term. It was suggested that this difference in performance was due to the Ascentis Express column has lower loading capacity and retention factor than even totally porous particles. The relation between the shell pore size and thickness was investigated to establish restricted diffusion of molecules [25] . The pore size was found to be the major contributor toward restricted diffusion of large protein molecules at 400 kDa, which was comparable to previous studies on the effect of pore size on molecules diffusion in totally porous particles]. The study involved the use of HaloC18 particles with pore sizes of 9, 16 and 40 nm for the separation of proteins such as myosin, ferritin, and _- amylase. Mass transfer kinetic could also be influenced by the shell thickness, thus the separation efficient separations either as, ideal a total peak capacity equal to the product of the first and separations [51] The is the long timescale involved incomprehensive 2D-LC. Run times can exceed several hours; how-ever theoretical peak capacities in the thousands can be achieved if a longer analysis time is acceptable [52, 53] . Examples of the use of fused core particles in 2D-LC include pharmaceutical and food analysis. In one study, the increased resolving power when using the reversed phase dual fused-core secondary columns confirmed the presence of minor components from the degradation of a drug compound. Very fast gradient separations were achieved at ambient temperature without excessive backpressure and without compromising optimal 1st dimension sampling rates [54] . In the analysis of pesticides in food, a totally porous HILIC column provided fast on-line clean-up of the samples in the first dimension, followed by analysis using a C18 core shell column. The method was shown to be capable of analyzing over 300 compounds with good sensitivity and robustness [55] . A layer of carbon could be deposited on 2.7m superficially porous silica microspheres without causing pore blockage. The use of these carbon clad core–shell silica as a new packing material in fast 2D-LCas the second dimension improved the peak capacity [56] Nine process related impurities detected in test sample of Apixaban by using newly developed RP-HPLC method. Forced degradation study was carried out under acidic, alkaline, oxidative, photolytic and thermal conditions to demonstrate the stability- indicating nature of the developed RP-HPLC method. the to the se and the back again. This is because diffusion only occurs via the poro us outer layer of the particle rather than the entire particle. In terms of s ize and shape core shell particles are remarkably constant which also he lps to separation efficiency by limiting variable analyte movement withi n the particles .instead of investing any costly UPHPLC systems, it is bett er to improve the efficiency of their existing HPLC systems by using core shell technology.
Chemistry,Medicine
What problem does this paper attempt to address?