Numerical and experimental study of a multiphase flow inside a self-contained drum motor drive system

Ahmed M. Teamah,Mohamed S. Hamed
DOI: https://doi.org/10.2139/ssrn.4524963
IF: 4.779
2024-01-19
International Journal of Thermal Sciences
Abstract:The multiphase Taylor-Couette flow of air and oil enclosed within the annular space between two concentric cylinders has been studied experimentally and numerically. The outer cylinder rotates at a constant speed and exchanges heat by convection and radiation with ambient air. The inner cylinder is stationary and subjected to a constant uniform heat flux. Such flow can be found in a self-contained drum motor drive system (SCDMDS). The heat flux imposed on the inner cylinder mimics the amount of heat generated due to several thermal losses within the SCDMDS. A layer of lagging material is sometimes added to the outer cylinder to enhance belt traction. The effect of the inner-to-outer cylinder radius ratio ( RR ), Reynolds number ( Re ), oil volume ( OV ), outer cylinder surface emissivity ( ε ), and lagging material thickness ( δ ) on the flow and heat transfer between the two cylinders and the ambient has been investigated considering a quasi-steady state analysis. The current investigation considered the following ranges found in a typical SCDMDS: RR = 0.35–0.85, Re = 200–3000, OV = 50–100 %, ε = 0–0.95, and δ = 0–100 mm. The numerical part of the present study has been carried out using ANSYS-CFX software package. The numerical results have been validated using experimental data. Results indicated that increasing RR, Re and ε enhanced the heat transfer within the SCDMDS. The rate of heat transfer within the annular space reached its highest value at OV = 65 % above which the rate of heat transfer is deteriorated. Because the lagging material is acting as an insulation over the outer cylinder, a critical thickness of δ = 35 mm resulted in the minimum overall resistance above which the rate of heat transfer is deteriorated. The parametric study revealed that the best overall thermal performance was attained at RR = 0.85, Reynolds number = 3000, OV = 65 %, ε = 0.95 and δ = 35 mm. In this case, the heat transfer coefficient between the inner cylinder and the oil reached its highest value of 410 W/m 2 °C, giving the lowest possible inner cylinder temperature. A correlation of Nusselt number in terms of the geometrical and operating parameters of a SCDMDS considered in the current study has been developed and validated. The developed correlation gave a maximum deviation of ±8 %.
engineering, mechanical,thermodynamics
What problem does this paper attempt to address?