Abstract TMP68: Proximal Balloon Occlusion With Forced Aspiration (POWER) Technique Should Be Effective in Preventing Distal Microembolization During Carotid Artery Stenting With the Filter Protection Device

Tomonari Saito,Kentaro Suzuki,Sotaro Shoda,Junki Yoshimura,Shinichiro Numao,yuji nishi,Takehiro Katano,Takuya Kanamaru,Noriko Matsumoto,Yasuhiro Nishiyama,Kazumi Kimura
DOI: https://doi.org/10.1161/str.55.suppl_1.tmp68
IF: 10.17
2024-02-01
Stroke
Abstract:Purpose: Since the balloon protection device became unavailable in Japan three years ago, the DWI-positive rate after carotid artery stenting (CAS) has increased. We have developed a Proximal balloon Occlusion With forcEd aspiRation (POWER) technique to prevent distal embolization in CAS with the filter protection device. The concept of this technique was to standardize the three points: (1) aspiration force, (2) timing of aspiration and (3) use of balloon guiding. To standardize (1), a VACLOK (vacuum pressure) syringe-like system was used instead of manual aspiration, so that the same aspiration force was applied. To standardize (2), aspiration was to be initiated just before PTA balloon deflation during pre- and post-dilatation. Methods: From June 2020 to the present, CAS cases using the Filter protection device were enrolled and divided into two groups before and after the introduction of the POWER technique. Patient backgrounds, carotid artery characteristics (symptomatic, stenosis rate and length, MRI and echographic findings), PTA balloon size, stent type, the postoperative DWI positive rate and the number of DWI spots, and the symptomatic stroke rate were compared between the two groups, respectively. Results: Of the 55 CAS cases, 36 were enrolled in the without-POWER group and 19 in the with-POWER group. Between the two groups, postoperative DWI positivity was 32 (88.9%) vs. 9 (47.4%) (p<0.001), DWI spot lesions (n, median (quartiles)) was 9 (3-20) vs. 0 (0-2) (p<0.001), and symptomatic stroke was 6 (16.7%) vs. 0 (0%) (p=0.06), all with-POWER group were less common. Symptomatic stenosis (63.9% vs. 94.7%, p<0.05) was more common in the with-POWER group. There were no differences in age, gender, stenosis rate and length, open cell stent, PTA balloon size, MRA TOF high, MRI T1BB high, hypoechoic plaque, HT, DL, DM, CKD, smoking or DAPT use. Conclusion: POWER technique was associated with lower postoperative DWI positivity and lesion counts in CAS with filter protection device.
peripheral vascular disease,clinical neurology
What problem does this paper attempt to address?