Slow conduction velocity predicts atrial fibrillation recurrence after radiofrequency ablation

Dan Qi,Xiaonan Guan,Xiaoqing Liu,Lifeng Liu,Zheng Liu,Jianjun Zhang
DOI: https://doi.org/10.1111/jce.16193
IF: 2.7
2024-01-29
Journal of Cardiovascular Electrophysiology
Abstract:Objective To evaluate the progression of electrophysiological phenomena in atrial fibrillation (AF) and elucidate the association between the left atrial conduction velocity (LACV) and AF recurrence after pulmonary vein isolation. Methods A total of 188 AF patients (121 paroxysmal AF and 67 persistent AF) who underwent PVI for the first time were enrolled in this prospective study. The left atrium was mapped using a 20‐pole electrode catheter combined with the CARTO3 system. The conduction distances and conduction times of the left atrium from the Bachmann bundle area to the mitral isthmus were calculated. Anterior, posterior, and septal LACV were calculated as conduction distance divided by conduction time. Results The anterior, posterior, and septal LACVs in the AF recurrence group were slower than those in the nonrecurrence group (anterior: 0.807 [0.766, 0.848] and 1.048 [1.000, 1.093] m/s, p
cardiac & cardiovascular systems
What problem does this paper attempt to address?