Organic Dots with Large π-Conjugated Planar for Cholangiography beyond 1500 nm in Rabbits: A Non-Radioactive Strategy

Di Wu,Shunjie Liu,Jing Zhou,Runze Chen,Yifan Wang,Zhe Feng,Hui Lin,Jun Qian,Ben Zhong Tang,Xiujun Cai
DOI: https://doi.org/10.1021/acsnano.0c09981
IF: 17.1
2021-03-12
ACS Nano
Abstract:Iatrogenic extrahepatic bile duct injury remains a dreaded complication while performing cholecystectomy. Although X-ray based cholangiography could reduce the incidence of biliary tract injuries, the deficiencies including radiation damage and expertise dependence hamper its further clinical application. The effective strategy for intraoperative cholangiography is still urgently required. Herein, a fluorescence-based imaging approach for cholangiography in the near-infrared IIb window (1500–1700 nm) using TT3-<i>o</i>CB, a bright aggregation-induced emission luminogen with large π-conjugated planar unit, is reported. In phantom studies, TT3-<i>o</i>CB nanoparticles exhibit high near-infrared IIb emission and show better image clarity at varying penetrating depths. When intrabiliary injected into the gallbladder or the common bile duct of the rabbit, TT3-<i>o</i>CB nanoparticles enable the real-time imaging of the biliary structure with deep penetrating capability and high signal-to-background ratio. Moreover, the tiny iatrogenic biliary injuries and the gallstones in established disease models could be precisely diagnosed by TT3-<i>o</i>CB nanoparticle assisted near-infrared IIb imaging. In summary, we reported a feasible application for aggregation-induced emission dots as biliary contrast agent and realized high-quality cholangiography in the near-infrared IIb window with precise diagnostic ability and nonradioactive damage, which could possibly be applied for intraoperative diagnosis.The Supporting Information is available free of charge at <a class="ext-link" href="/doi/10.1021/acsnano.0c09981?goto=supporting-info">https://pubs.acs.org/doi/10.1021/acsnano.0c09981</a>.DLS profile in water, absorption spectra, NIR-IIb emission spectra, NIR-IIb fluorescence intensity measurement, ICG assisted NIR-IIb cholangiography, SBRs calculation, 3 mm adipose tissue phantom model, cell viability analysis, removal and clearance of TT3-<i>o</i>CB NPs, fluorescence intensity measurement of TT3-<i>o</i>CB NPs in organs, experimental methods (<a class="ext-link" href="/doi/suppl/10.1021/acsnano.0c09981/suppl_file/nn0c09981_si_001.pdf">PDF</a>)This article has not yet been cited by other publications.
materials science, multidisciplinary,chemistry, physical,nanoscience & nanotechnology
What problem does this paper attempt to address?
The problem that this paper attempts to solve is to achieve high - quality intraoperative cholangiography in biliary tract surgery, especially for the diagnosis of extrahepatic biliary tract injuries. Although traditional X - ray cholangiography can reduce the incidence of biliary tract injuries, it has disadvantages such as radiation damage and high dependence on the operator's skills, which limit its wide application in clinical practice. Therefore, a non - radioactive intraoperative biliary tract imaging strategy is required to overcome these limitations. For this purpose, the research team has developed a fluorescence - imaging - based method, using TT3 - oCB nanoparticles as a contrast agent to perform biliary tract imaging in the near - infrared IIb window (1500 - 1700 nm). This method not only avoids radioactive damage, but also has high penetration ability and high signal - to - noise ratio, can display biliary tract structures in real - time and clearly, and accurately diagnose minor iatrogenic biliary tract injuries and cholelithiasis. Through rabbit model experiments, the feasibility and superiority of TT3 - oCB nanoparticles in biliary tract imaging have been verified, showing their potential application value in intraoperative diagnosis.