Tetraphenylethylene fluorophore based AIE-fluorescent probe for detection of ATP in mitochondria

Bin Yang,Wangbo Qu,Taiyu Guo,Ruowei Tian,Shuang Qiu,Xinyue Chen,Zhirong Geng,Zhilin Wang
DOI: https://doi.org/10.1016/j.dyepig.2023.111295
IF: 5.122
2023-07-01
Dyes and Pigments
Abstract:A tetraphenylethylene fluorophore based on D-π-A structure was employed to design and synthesize the TPE-Py-FP probe for selective detection of ATP. TPE-Py-FP had the advantages of large Stokes shift, great hydrophilicity and good selectivity. Especially, the pyridine portion and quaternary ammonium structure of TPE-Py-FP had positively charged sites, which could be used as recognition groups to interact with the negatively charged triphosphate structure of ATP. Then the fluorescence emission of TPE-Py-FP at 580 nm showed a “turn-on” response after adding ATP. Moreover, this probe could rapidly respond to ATP over a wide linear range of 10–120 μM and the limit of detection (LOD) was 2.76 μM. The zeta potential and dynamic light scattering experiments revealed that the detection mechanism was mainly the electrostatic adsorption interaction between the dual positively charged sites of TPE-Py-FP and the negatively charged triphosphate structure of ATP. Additionally, TPE-Py-FP could localize in mitochondria specifically with a Pearson's coefficient of 0.81, and show great utility in monitoring the fluctuation of mitochondrial ATP level.
engineering, chemical,chemistry, applied,materials science, textiles
What problem does this paper attempt to address?
The problem that this paper attempts to solve is to develop a sensitive and efficient analytical method to monitor the ATP level in mitochondria. Specifically, the authors designed and synthesized a new fluorescent probe TPE - Py - FP based on the tetraphenylethylene (TPE) fluorophore for the selective detection of ATP. TPE - Py - FP has the following advantages: 1. **Large Stokes shift**: This makes the probe less affected by background fluorescence during the detection process. 2. **Good water solubility**: This is helpful for the application of the probe in biological systems. 3. **High selectivity**: TPE - Py - FP can specifically bind to ATP and is not sensitive to other biomolecules. 4. **Fast response**: TPE - Py - FP can rapidly respond to ATP within a wide linear range (10–120 μM), with a detection limit (LOD) of 2.76 μM. 5. **Mitochondrial localization ability**: TPE - Py - FP can specifically localize in mitochondria, with a Pearson correlation coefficient of 0.81, indicating that its localization in mitochondria is very accurate. Through these characteristics, the TPE - Py - FP probe can effectively monitor the changes in ATP levels in mitochondria, which is of great significance for studying cell energy metabolism, signal transduction, and diseases related to abnormal ATP levels (such as ischemia, cardiovascular diseases, colitis, Parkinson's disease, and malignant tumors).