Unmasking of the temperature window and mechanism for “loss of passivation” effect of a Cr-13 type martensite stainless steel

Gaoyang Wei,Siyuan Lu,Shuxin Li,Kefu Yao,Hengwei Luan,Xufei Fang
DOI: https://doi.org/10.1016/j.corsci.2020.108951
IF: 7.72
2020-12-01
Corrosion Science
Abstract:<p>In this work, the essential mechanism of "loss of passivation" (LOP) effect for a 13 wt. % Cr-type martensitic stainless steel (MSS) is studied via electrochemical and microstructure approaches. The MSSs were quenched at 1030 °C and then tempered at 440−600 °C. Electrochemical results show that the tempering range for "LOP" is 460−540 °C. Severe corrosion occurred on 520 °C-tempered MSS after being immersed in Cl<sup>−</sup> containing solution for 35 min. Transmission electron microscopy (TEM) observation towards the corroded area of 1030-520 sample reveals the massive precipitation of nano-sized Cr-rich carbides, which is the essential cause for the "LOP" of MSSs.</p>
materials science, multidisciplinary,metallurgy & metallurgical engineering
What problem does this paper attempt to address?