"Closed Proportional-Integral-Derivative-Loop Model" Following Control

Oluwasegun Ayokunle Somefun,Kayode Akingbade,Folasade Dahunsi
DOI: https://doi.org/10.48550/arXiv.2006.00314
2020-05-30
Systems and Control
Abstract:The proportional-integral-derivative (PID) control law is often overlooked as a computational imitation of the critic control in human decision. This paper provides a formulation to remedy this problem. Further, based on the characteristic settling-behaviour of dynamical systems, the "closed PID-loop model" following control (CPLMFC) method is introduced for automatic PID design. Also, a method for closed-loop settling-time identification is provided. The CPLMFC algorithm and some recommended guidelines are given for setting the critic weights of the PID. Finally, two representative case-studies are simulated. Both the theoretical results and simulation results (via performance indices) illustrate that the CPLMFC can guarantee both accurate and stable closed-loop adaptive PID control performance in real-time
What problem does this paper attempt to address?