Resolved Infrared Spectroscopy of Aqueous Molecules Employing Tunable Graphene Plasmons in an Otto Prism

Jinpeng Nong,Wei Wei,Guilian Lan,Peng Luo,Caicheng Guo,Juemin Yi,Linlong Tang
DOI: https://doi.org/10.1021/acs.analchem.0c02733
IF: 7.4
2020-09-22
Analytical Chemistry
Abstract:Real-time and <i>in situ</i> detection of aqueous solution is essential for bioanalysis and chemical reactions. However, it is extremely challenging for infrared microscopic measurement because of the large background of water absorption. Here, we proposed a wideband-tunable graphene plasmonic infrared biosensor to detect biomolecules in an aqueous environment, employing attenuated total reflection in an Otto prism configuration and tightly confined plasmons in graphene nanoribbons. Benefiting from the graphene plasmonic electric field enhancement, such a biosensor is able to identify the molecular chemical fingerprints without the interference of water absorption. As a proof of concept, the recombinant protein AG and goat anti-mouse immunoglobulin G (IgG) are used as the sensing analytes, of which the vibrational modes (1669 and 1532 cm<sup>–1</sup>) are very close to the OH-bending mode of water (1640 cm<sup>–1</sup>). Simulation results show that the fingerprints of protein molecules in the water environment can be selectively enhanced. Therefore, the water absorption is successfully suppressed so that two protein modes can be resolved by sweeping graphene Fermi energy in a wide waveband. By further optimizing the incident angle and graphene mobility to improve the mode energy of graphene plasmons, maximum enhancement factors of 112 and 130 can be achieved for amide I and II bands. Our work provides an effective approach for the highly sensitive and selective <i>in situ</i> identification of aqueous-phase molecular fingerprints in fields of healthcare, food safety, and biochemical sensing.The Supporting Information is available free of charge at <a class="ext-link" href="/doi/10.1021/acs.analchem.0c02733?goto=supporting-info">https://pubs.acs.org/doi/10.1021/acs.analchem.0c02733</a>.Effect of the spacer thickness on the resonant wavelength and absorption. Comparison of the background water absorption in different configurations. Calculation of the extinction spectra in the water environment. Extracted vibrational signals from the extinction spectra. Resolving the molecular fingerprint in a wider wavelength region. Effect of the incident angle and graphene mobility on the plasmonic response (<a class="ext-link" href="/doi/suppl/10.1021/acs.analchem.0c02733/suppl_file/ac0c02733_si_001.pdf">PDF</a>)This article has not yet been cited by other publications.
chemistry, analytical
What problem does this paper attempt to address?