Amplification-free Detection of Cytomegalovirus miRNA Using a Modification-free Surface Plasmon Resonance Biosensor

Ying-Feng Chang,Yi-Te Chou,Chia-Yu Cheng,Jen-Fu Hsu,Li-Chen Su,Ja-an Annie Ho
DOI: https://doi.org/10.1021/acs.analchem.1c01093
IF: 7.4
2021-05-24
Analytical Chemistry
Abstract:Cytomegalovirus (CMV) is the most frequent cause of congenital infection worldwide; congenital CMV may lead to significant mortality, morbidity, or long-term sequelae, such as sensorineural hearing loss. The current study presents a newly designed surface plasmon resonance (SPR) biosensor for CMV-specific microRNAs that does not involve extra care for receptor immobilization or treatment to prevent fouling on bare gold surfaces. The modification-free approach, which utilizes a poly-adenine [poly(A)]–Au interaction, exhibited a high affinity that was comparable to that of the gold–sulfur (Au–S) interaction. In addition, magnetic nanoparticles (MNPs) were used to separate the analyte from complex sample matrixes that significantly reduced nonspecific adsorption. Moreover, the MNPs also played an important role in SPR signal amplification due to the binding-induced change in the refractive index. Our SPR biosensing platform was used successfully for the multi-detection of the microRNAs, UL22A-5p, and UL112-3p, which were associated with CMV. Our SPR biosensor offered the detection limits of 108 fM and 24 fM for UL22A-5p and UL112-3p, respectively, with an <i>R</i><sup>2</sup> of 0.9661 and 0.9985, respectively. The precision of this biosensor has an acceptable CV (coefficient of variation) value of &lt;10%. In addition, our sensor is capable of discriminating between serum samples collected from healthy and CMV-infected newborns. Taken together, we believe that our newly developed SPR biosensing platform is a promising alternative for the diagnosis of CMV-specific microRNA in clinical settings, and its application for the detection of other miRNAs may be extended further.The Supporting Information is available free of charge at <a class="ext-link" href="/doi/10.1021/acs.analchem.1c01093?goto=supporting-info">https://pubs.acs.org/doi/10.1021/acs.analchem.1c01093</a>.Comparison of the proposed SPR biosensing platform and the recent SPR-based sensors, performance and specificity of our probing system, optimization of the poly(A) polymerase concentration, reaction time for the poly(A) extension procedure performed at 37 °C, kinetic plots of accumulated poly(A) products using various concentrations of poly(A) polymerase (0, 0.05, 0.125, 0.25, and 0.5 U/μL), and specificity of the cp-MNPs toward two targets, UL22A-5p and UL112-3p, and three commonly studied miRNAs (miR-221, miR-let71, and miR-21) (<a class="ext-link" href="/doi/suppl/10.1021/acs.analchem.1c01093/suppl_file/ac1c01093_si_001.pdf">PDF</a>)This article has not yet been cited by other publications.
chemistry, analytical
What problem does this paper attempt to address?