Development of a density-based topology optimization of homogenized lattice structures for individualized hip endoprostheses and validation using micro-FE

Patrik Müller,Alexander Synek,Timo Stauß,Carl Steinnagel,Tobias Ehlers,Paul Christoph Gembarski,Dieter Pahr,Roland Lachmayer
DOI: https://doi.org/10.1038/s41598-024-56327-4
IF: 4.6
2024-03-10
Scientific Reports
Abstract:Prosthetic implants, particularly hip endoprostheses, often lead to stress shielding because of a mismatch in compliance between the bone and the implant material, adversely affecting the implant's longevity and effectiveness. Therefore, this work aimed to demonstrate a computationally efficient method for density-based topology optimization of homogenized lattice structures in a patient-specific hip endoprosthesis. Thus, the root mean square error (RMSE) of the stress deviations between the physiological femur model and the optimized total hip arthroplasty (THA) model compared to an unoptimized-THA model could be reduced by 81 % and 66 % in Gruen zone (GZ) 6 and 7. However, the method relies on homogenized finite element (FE) models that only use a simplified representation of the microstructural geometry of the bone and implant. The topology-optimized hip endoprosthesis with graded lattice structures was synthesized using algorithmic design and analyzed in a virtual implanted state using micro-finite element (micro-FE) analysis to validate the optimization method. Homogenized FE and micro-FE models were compared based on averaged von Mises stresses in multiple regions of interest. A strong correlation (CCC > 0.97) was observed, indicating that optimizing homogenized lattice structures yields reliable outcomes. The graded implant was additively manufactured to ensure the topology-optimized result's feasibility.
multidisciplinary sciences
What problem does this paper attempt to address?
### Problems the paper attempts to solve This paper aims to solve the stress shielding problem caused by the mismatch of mechanical properties between materials and bones after hip prosthesis implantation. Specifically, the objectives of the paper are: 1. **Propose a density - based topology optimization method**: It is used to synthesize the graded lattice structure in the hip prosthesis to restore the stress state of the pre - operative bone. 2. **Verify using the micro - finite element (micro - FE) model**: Considering the microstructural geometric features of the lattice and bone tissue, verify the reliability of the optimization method. 3. **Demonstrate the feasibility of realizing the optimized prosthesis through additive manufacturing technology**: Ensure the practical manufacturability of the topology optimization results. ### Background and motivation - **Stress shielding phenomenon**: When the stiffness of the metal prosthesis is greater than that of the surrounding bone, the prosthesis will resist external forces, resulting in a decrease in mechanical stimulation of adjacent tissues, which in turn causes the gradual degeneration and loss of bone mass. This is particularly crucial in hip replacement surgery because the decrease in bone density will affect the secondary stability and service life of the prosthesis. - **Limitations of existing methods**: Although previous studies have proposed methods for optimizing hip prostheses using lattice structures, these methods usually rely on simplified homogenized finite element models and lack verification of the actual microstructure. - **Innovation points**: This paper provides a more accurate optimization and verification method by combining the homogenized finite - element model and the high - resolution micro - finite - element model, ensuring that the mechanical properties of the prosthesis after implantation are close to those of the pre - operative bone. ### Method overview 1. **Image processing**: Extract bone tissue from high - resolution CT scan data and construct a homogenized finite - element model in the physiological state. 2. **Topology optimization**: Use the homogenized finite - element model for density - based topology optimization to generate a graded density field to restore the stress state of the pre - operative bone. 3. **Lattice structure synthesis**: Convert the optimized density field into a graded lattice structure and achieve automated synthesis through algorithm design. 4. **Micro - finite - element analysis**: Use the micro - finite - element model to verify the optimized prosthesis to ensure that its mechanical properties at the micro - scale meet expectations. 5. **Additive manufacturing**: Manufacture the optimized prosthesis through laser powder bed fusion (LPBF) technology to verify its manufacturability. ### Results and significance - **Optimization effect**: Through the comparative analysis of the homogenized finite - element model and the micro - finite - element model, the stress deviations of the optimized prosthesis in Gruen zones 6 and 7 are reduced by 81% and 66% respectively. - **Verification reliability**: The average von Mises stress of the optimized prosthesis in the micro - finite - element model is highly correlated with the bone in the physiological state (CCC > 0.97), indicating the effectiveness of the optimization method. - **Manufacturing feasibility**: The optimized prosthesis has been successfully manufactured through additive manufacturing technology, demonstrating the feasibility of its practical application. In conclusion, this paper provides a new solution to solve the stress shielding problem of hip prostheses by proposing an efficient density - based topology optimization method and combining it with a high - resolution micro - finite - element model for verification.