Exergy analysis and exergetic sustainability index of package boiler

N.A. Serigianto,Muhammad Djoni Bustan,Sri Haryati
DOI: https://doi.org/10.1504/ijex.2024.138750
2024-05-31
International Journal of Exergy
Abstract:Energy utilisation in the fertiliser industry can be improved by conserving energy. One way to achieve this is by modifying the operating conditions of the package boiler. Research shows that 94.3% of the total exergy destruction of the package boiler is obtained from the evaporator component with a value of 2.7 × 10 8 kJ/hour. The modification of evaporator operating conditions involves lowering the inlet temperature of boiler feed water (BFW) by ΔT (196°C-116°C). This decrease in BFW temperature increases the latent heat required and reduces the convection heat carried by the flue gas to produce superheated steam. The optimum temperature of BFW is 161°C which results in a reduction in exergy destruction of 6.2 × 10 6 kJ/hour and produces a difference in loss costs based on actual data (196°C) of Rp 1,370,354,743/hour. The exergetic sustainability index (ESI) obtained was 0.918.
energy & fuels,thermodynamics
What problem does this paper attempt to address?