Rapid and Easy Detection of Microcystin-LR Using a Bioactivated Multi-Walled Carbon Nanotube-Based Field-Effect Transistor Sensor

Myeongsoon Lee,Seong H. Kim,Don Kim,Hak Jun Kim
DOI: https://doi.org/10.3390/bios14010037
2024-01-12
Biosensors
Abstract:In this study, we developed a multi-walled carbon nanotube (MWCNT)-based field-effect transistor (MWCNT-FET) sensor with high sensitivity and selectivity for microcystin-LR (MC-LR). Carboxylated MWCNTs were activated with an MC-LR-targeting aptamer (MCTA). Subsequently the bioactivated MWCNTs were immobilized between interdigitated drain (D) and source (S) electrodes through self-assembly. The top-gated MWCNT-FET sensor was configured by dropping the sample solution onto the D and S electrodes and immersing a Ag/AgCl electrode in the sample solution as a gate (G) electrode. We believe that the FET sensor's conduction path arises from the interplay between the MCTAs, with the applied gate potential modulating this path. Using standard instruments and a personal computer, the sensor's response was detected in real-time within a 10 min time frame. This label-free FET sensor demonstrated an impressive detection capability for MC-LR in the concentration range of 0.1–0.5 ng/mL, exhibiting a lower detection limit of 0.11 ng/mL. Additionally, the MWCNT-FET sensor displayed consistent reproducibility, a robust selectivity for MC-LR over its congeners, and minimal matrix interferences. Given these attributes, this easily mass-producible FET sensor is a promising tool for rapid, straightforward, and sensitive MC-LR detection in freshwater environments.
chemistry, analytical,nanoscience & nanotechnology,instruments & instrumentation
What problem does this paper attempt to address?
The paper aims to develop a rapid and simple method for detecting microcystin-LR (MC-LR). MC-LR is a toxic compound produced by cyanobacteria, particularly common in warm climates and eutrophic freshwater environments. Due to its potential health hazards, the World Health Organization recommends that the concentration of MC-LR in drinking water should be below 1 μg/L. The method proposed in the paper is based on a field-effect transistor (FET) sensor using multi-walled carbon nanotubes (MWCNT). Specifically, the research team chemically reacted MWCNT with an aptamer (MCTA) specific to MC-LR to prepare a bio-activated MWCNT. This bio-activated MWCNT was then fixed between the drain (D) and source (S) electrodes of the FET sensor. When the target molecule MC-LR is present, it specifically binds to MCTA, causing a change in the conductive path between the MWCNTs, thereby altering the sensor's resistance. This change can be enhanced by applying a gate voltage to boost the signal response. The FET sensor can achieve rapid detection of MC-LR (within 10 minutes), with high sensitivity (detection limit as low as 0.11 ng/mL), good selectivity, and reproducibility, effectively reducing matrix interference. Therefore, this sensor is highly suitable for on-site rapid detection of MC-LR, especially in remote areas or in cases where water sources are contaminated.