Design and operation of park-level integrated energy systems in various climate zones in China

Xin Zhao,Yanqi Chen,Kangxiang Liu,Gang Xu,Heng Chen,Wenyi Liu
DOI: https://doi.org/10.1016/j.scs.2023.104705
IF: 11.7
2023-06-08
Sustainable Cities and Society
Abstract:Park-level integrated energy systems (PIESs) have a unique role in developing communities' energy infrastructure in more economical and sustainable ways. The design and operation of a PIES depend on the energy demand of buildings, which could be significantly affected by climate change. This paper presented the PIES in China's different climate zones (Harbin, Dalian, Changsha, and Haikou). The PIES integrating natural gas, solar and geothermal energy simultaneously produces electric, heating and cooling loads. A two-stage optimal approach was proposed in this paper to model the PIES mathematically. In the first stage, the worst-case scenario was obtained by the confidence interval combination method to optimize the minimum total cost. In the second stage, the operation strategies of following electric loads and following thermal loads were used to optimize the operation cost. The results revealed that the annual total cost of the PIES presented a v–shaped cost curve with the power generation unit (PGU) capacity from 400 kW to 2000 kW. PIES-1, located in Dalian, had the lowest total cost of 0.18 million to $0.01 million. Moreover, PIES-1, located in Harbin, had the lowest CO 2 emissions.
energy & fuels,construction & building technology,green & sustainable science & technology