Abstract:The rapid development of soft electronics has revitalized the research of conducting elastomers. However, the design of conducting elastomers having high stretchability and good transparency still remains a considerable challenge. In this study, we develop a highly transparent, stretchable, and conducting ionoelastomer based on a poly(ionic liquid) in which cations are fixed to a stretchable elastomeric network and counter anions are mobile. The ionoelastomer solves the dilemma of simultaneous transparency and stretchability in the design of traditional conducting elastomers, possessing good transparency (96%) with an extraordinarily high stretchability, up to a limiting strain of 1460%. Moreover, this novel material is completely nonvolatile and nonhygroscopic, endowing the ionoelastomer with highly stable thermal, environmental, electrochemical, and mechanoelectrical properties. An underwater sensor based on the ionoelastomer is developed with good performance in an aqueous environment. Also, a transparent dielectric elastomer actuator (DEA) is demonstrated using the ionoelastomer. It is believed that the ionoelastomer would pave the way to develop exceptional conducting elastomers toward next-generation soft electronics.The Supporting Information is available free of charge at <a class="ext-link" href="/doi/10.1021/acsami.1c05833?goto=supporting-info">https://pubs.acs.org/doi/10.1021/acsami.1c05833</a>.Synthetic details, schemes, and characterizations of [EIC<sub>6</sub>A][TFSI]; EDX elemental mapping; frequency dependence of capacitance; stress–strain curves at different crosslinker contents and comonomer contents; DMA profiles at frequency sweeping and temperature sweeping; mass loss and conductivity after the extraction; FTIR spectrum before and after curing; TGA thermogram in N<sub>2</sub> and air; the weight maintenance of PAAm–NaCl conducting hydrogel in open air; photographs of the ionoelastomer–metal junctions; the strain dependence of resistance change; relative resistance change as a function of strain; cyclic relative resistance change; the water contact angle; photographs showing the ionoelastomer-based underwater sensor (<a class="ext-link" href="/doi/suppl/10.1021/acsami.1c05833/suppl_file/am1c05833_si_001.pdf">PDF</a>)Good adhesion of ionoelastomer on steel and copper electrodes (Movie S1) (<a class="ext-link" href="/doi/suppl/10.1021/acsami.1c05833/suppl_file/am1c05833_si_002.mp4">MP4</a>)Ionoelastomer-based underwater sensor in tap water (Movie S2) (<a class="ext-link" href="/doi/suppl/10.1021/acsami.1c05833/suppl_file/am1c05833_si_003.mp4">MP4</a>)Electrical actuation of ionoelastomer-based transparent DEA under 4.2 kV (Movie S3) (<a class="ext-link" href="/doi/suppl/10.1021/acsami.1c05833/suppl_file/am1c05833_si_004.mp4">MP4</a>)Electrical breakdown of ionogel-based transparent DEA under 1.5 kV (Movie S4) (<a class="ext-link" href="/doi/suppl/10.1021/acsami.1c05833/suppl_file/am1c05833_si_005.mp4">MP4</a>)This article has not yet been cited by other publications.
materials science, multidisciplinary,nanoscience & nanotechnology
What problem does this paper attempt to address?