Phase-retrieval algorithm based on Kramers–Kronig relations in coherent diffraction imaging
Ying Wang,Jianhui Zhou,Jiyang Ou,Jie Guo,Cailian Yang,Xiaoqiang Zhang,Peng Xu,Make Ying,Yanxia Xu,Qinghong Zhou,Tao Liu
DOI: https://doi.org/10.1088/2040-8986/aca917
IF: 2.1
2022-12-07
Journal of Optics
Abstract:Coherent diffraction imaging (CDI) is a high-resolution technique that does not require X-ray lenses. With advances in scientific technology, such as synchrotron radiation, X-ray free-electron lasers, and coherent electron sources, CDI has been applied to diverse fields, such as biology, medicine, and semiconductors, as a high-resolution, nondestructive measure. With the rapid increase in demand for these applications, enhancing the efficiency of processing high-volume data has become a significant challenge for promotion. In this study, we proposed an algorithm that combines Kramers–Kronig (KK) relations with oversampling smoothness (OSS). The results were evaluated by introducing an error coefficient. We found that the error of the KK-OSS algorithm is always reduced by approximately 50% compared with the error reduction (ER) algorithm and OSS in real space. In the diffraction space, the error in the KK-OSS decreased by 15%. With 100 iterations, KK-OSS spent 163.1 s on reconstructing most of the sample information, while ER took 258.1 s and the reconstruction was still a random value. In Fraunhofer diffraction, it cost KK-OSS 58.8 s to reconstruct, while OSS took 61.9 s. Therefore, this method can reduce the reconstruction error, shorten the reconstruction time, and improve the efficiency compared with the ER and OSS algorithm using a random phase as the initial value.
optics