Abstract:This research presents a novel fault-tolerant predictive power control method for a Doubly-fed induction generator (DFIG) used in wind turbine control systems. Due to the proposed control mechanism, the system can continue to function effectively despite open-circuit or short-circuit faults in the insulated-gate bipolar transistors (IGBTs) of the MPC controller. Depending on the type of problem and its location, the tolerant IGBT overcomes power oscillations and limits the power converter's potential switching states. By monitoring the optimal generator speed, wind turbine control systems strive to maximize power output. For wind turbines operating in the partial-load area, a fault-tolerant model predictive control strategy is recommended in order to achieve control goals despite disturbances, uncertainties, sensor, and actuator difficulties. A high order sliding mode observer (HOSMO) is used to evaluate both the actual states and sensor-faults at the same time. A high order sliding mode (HOSM) control strategy based on the MPC controller is used to regulate the speed of wind turbines in order to harness the wind's maximum power.
automation & control systems,engineering, electrical & electronic
What problem does this paper attempt to address?
The paper aims to address the fault-tolerant control issue of Doubly-Fed Induction Generators (DFIG) in wind power generation systems when facing Insulated Gate Bipolar Transistor (IGBT) open-circuit or short-circuit faults. The study proposes a novel fault-tolerant predictive power control method based on a High-Order Sliding Mode Observer (HOSMO) and Model Predictive Controller (MPC). By monitoring the optimal generator speed, this method can maximize the power output of the wind turbine in the presence of disturbances, uncertainties, sensor, and actuator issues. Additionally, HOSMO is used to simultaneously assess the actual state and sensor faults, thereby enhancing the robustness and reliability of the system. Overall, the study aims to achieve effective control of wind turbines in partial load regions and demonstrates the effective performance of the proposed MPC controller combined with the High-Order Sliding Mode Observer.