Endoscopic submucosal dissection of Barrett's neoplasia using adaptive multipolar traction combined with line: report of two cases

Jean Grimaldi,Louis-Jean Masgnaux,Alexandru Lupu,Timothée Wallenhorst,Jérôme Rivory,Jérémie Jacques,Mathieu Pioche
DOI: https://doi.org/10.1055/a-2217-3544
2024-01-10
Endoscopy
Abstract:Endoscopic submucosal dissection (ESD) is the gold standard for the resection of visible lesions of >15 mm in Barrett's neoplasia [1]. Recently, the "tunnel + traction with a line" strategy has shown encouraging results in terms of safety and efficacy [2] [3]. However, the traction with a line technique has the disadvantage of exerting a traction force that is quasi-tangential to the plane of the submucosa. We believed that combining this with the ATRACT 2+2 adaptive multitraction device ([Fig. 1]) [4] [5] would enable a 90° traction force to be exerted, which could also be increased during the procedure. We report here on two patients referred for ESD resection of Barrett esophagus (BE), using the adaptive multipolar traction combined with a line ([Video 1]). The first patient presented with a Barrett's neoplasia within a pseudodiverticular hiatal hernia. After a circumferential incision had been made at the distal pole, two tunnels (anterior and posterior) were made. The ATRACT 2+2 device attached to a line was then placed with three points on the proximal edge and one point on the distal edge, so as to obtain an optimum 90° angle of traction. The line attached to the ATRACT 2+2 device prevents the lesion from tilting towards the stomach during the procedure. After two-thirds of the dissection had been completed, the ATRACT 2+2 device was tightened to increase the traction ([Fig. 2]) and facilitate completion of the procedure ([Fig. 3]). The second patient underwent a near-circumferential BE dissection, using a similar strategy. The two procedures were carried out by two different operators. The dissections enabled en bloc resection of both lesions, the first corresponding to an intramucosal adenocarcinoma and the second to a T1b sm2 adenocarcinoma. There were no complications, in particular no perforations, during the procedures. Further investigations are needed to evaluate the efficacy of the multipolar adaptive traction device combined with a clip-and-line traction strategy for the resection of esophageal lesions, but the technique seems promising. Endoscopy_UCTN_Code_TTT_1AO_2AG E-Videos is an open access online section of the journal Endoscopy , reporting on interesting cases and new techniques in gastroenterological endoscopy. All papers include a high-quality video and are published with a Creative Commons CC-BY license. Endoscopy E-Videos qualify for HINARI discounts and waivers and eligibility is automatically checked during the submission process. We grant 100% waivers to articles whose corresponding authors are based in Group A countries and 50% waivers to those who are based in Group B countries as classified by Research4Life (see: https://www.research4life.org/access/eligibility/). This section has its own submission website athttps://mc.manuscriptcentral.com/e-videos. Article published online: 09 January 2024 © 2024. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution License, permitting unrestricted use, distribution, and reproduction so long as the original work is properly cited. (https://creativecommons.org/licenses/by/4.0/). Georg Thieme Verlag KG Rüdigerstraße 14, 70469 Stuttgart, Germany
gastroenterology & hepatology,surgery
What problem does this paper attempt to address?