Quantitative Detection of Cathepsin B Activity in Neutral pH Buffers Using Gold Microelectrode Arrays: Toward Direct Multiplex Analyses of Extracellular Proteases in Human Serum

Yang Song,Jestin Gage Wright,Morgan J. Anderson,Sabari Rajendran,Zhaoyang Ren,Duy H. Hua,Jessica E. Koehne,M. Meyyappan,Jun Li
DOI: https://doi.org/10.1021/acssensors.1c01175
IF: 8.9
2021-09-21
ACS Sensors
Abstract:Proteases are critical signaling molecules and prognostic biomarkers for many diseases including cancer. There is a strong demand for multiplex bioanalytical techniques that can rapidly detect the activity of extracellular proteases with high sensitivity and specificity. This study demonstrates an activity-based electrochemical biosensor of a 3 × 3 gold microelectrode array for the detection of cathepsin B activity in human serum diluted in a neutral buffer. Proteolysis of ferrocene-labeled peptide substrates functionalized on 200 × 200 μm microelectrodes is measured simultaneously over the nine channels by AC voltammetry. The protease activity is represented by the inverse of the exponential decay time constant (1/τ), which equals to (kcat/KM)[CB] based on the Michaelis–Menten model. An enhanced activity of the recombinant human cathepsin B (rhCB) is observed in a low-ionic-strength phosphate buffer at pH = 7.4, giving a very low limit of detection of 8.49 × 10–4 s–1 for activity and 57.1 pM for the active rhCB concentration that is comparable to affinity-based enzyme-linked immunosorbent assay (ELISA). The cathepsin B presented in the human serum sample is validated by ELISA, which mainly detects the inactive proenzyme, while the electrochemical biosensor specifically measures the active cathepsin B and shows significantly higher decay rates when rhCB and human serum are activated. Analyses of the kinetic electrochemical measurements with spiked active cathepsin B in human serum provide further assessment of the protease activity in the complex sample. This study lays the foundation to develop the gold microelectrode array into a multiplex biosensor for rapid detection of the activity of extracellular proteases toward cancer diagnosis and treatment assessment.The Supporting Information is available free of charge at https://pubs.acs.org/doi/10.1021/acssensors.1c01175.Detailed materials and instruments used in this study, Au MEA fabrication procedures, procedures for ELISA measurements, derivation of the Michaelis–Menten model for electrochemical data analysis, and additional electrochemical kinetic proteolysis results of Au MEA in different buffers and in 5% human serum samples (PDF)This article has not yet been cited by other publications.
chemistry, multidisciplinary, analytical,nanoscience & nanotechnology
What problem does this paper attempt to address?