Cyclic Ion Mobility for Hydrogen/Deuterium Exchange-Mass Spectrometry Applications

Damon Griffiths,Malcolm Anderson,Keith Richardson,Satomi Inaba-Inoue,William J Allen,Ian Collinson,Konstantinos Beis,Michael Morris,Kevin Giles,Argyris Politis
DOI: https://doi.org/10.1021/acs.analchem.3c05753
IF: 7.4
2024-04-02
Analytical Chemistry
Abstract:Hydrogen/deuterium exchange-mass spectrometry (HDX-MS) has emerged as a powerful tool to probe protein dynamics. As a bottom-up technique, HDX-MS provides information at peptide-level resolution, allowing structural localization of dynamic changes. Consequently, the HDX-MS data quality is largely determined by the number of peptides that are identified and monitored after deuteration. Integration of ion mobility (IM) into HDX-MS workflows has been shown to increase the data quality by providing...
chemistry, analytical
What problem does this paper attempt to address?
### Problems the paper attempts to solve This paper aims to improve the data quality and sequence coverage of hydrogen - deuterium exchange mass spectrometry (HDX - MS) in analyzing complex protein samples (especially membrane proteins) by introducing the cyclic ion mobility (cIM) technique. Specifically, the paper attempts to solve the following problems: 1. **Improve data quality**: - HDX - MS is a powerful tool for studying protein dynamics and structural changes. However, the traditional HDX - MS workflow often faces problems of low sequence coverage and redundancy when dealing with complex samples such as membrane proteins. - By integrating the ion mobility (IM) technique, orthogonal peptide ion separation in the gas phase can be provided, thus improving data quality. 2. **Enhance the analysis ability of complex samples**: - Membrane proteins (such as G - protein - coupled receptors GPCRs) usually require complex screening and optimization conditions to obtain high - quality HDX - MS results. - The cyclic ion mobility (cIM) technique has higher resolution and can better separate complex peptide mixtures, thus enhancing the analysis ability of these complex samples. 3. **Improve multi - channel cIM data processing**: - Traditional data processing methods are insufficient in processing multi - channel cIM data, resulting in some high - quality peptide spectra not being recognized. - The paper proposes a new data processing strategy that can better handle multi - channel cIM data, thus increasing the peptide recognition rate. ### Main findings 1. **Performance improvement of single - channel cIM**: - Using the single - channel cIM technique, compared with the traditional SYNAPT G2 - Si instrument, the number of recognized peptides increases significantly, especially in membrane protein samples. - This improvement not only increases the sequence coverage but also the peptide redundancy, thus improving the resolution and accuracy of the data. 2. **Unique advantages of multi - channel cIM**: - Although the multi - channel cIM technique performs worse than the single - channel cIM in some cases, it can recognize some unique peptide populations. - By combining single - channel and multi - channel cIM data, the number of recognized peptides can be further increased, thus improving the overall sequence coverage and redundancy. 3. **New data processing strategy**: - The paper proposes a new data processing method. By adjusting the drift time full - width - at - half - maximum (drift FWHM) trend line, it can better handle multi - channel cIM data. - This method significantly increases the peptide recognition rate, especially in complex samples. ### Conclusion By introducing the cyclic ion mobility (cIM) technique and the improved data processing method, this paper successfully improves the data quality and sequence coverage of hydrogen - deuterium exchange mass spectrometry (HDX - MS) in analyzing complex membrane protein samples. This provides new ideas and methods for analyzing complex samples in future HDX - MS and other mass spectrometry applications on substrates.