A Flexible Aptameric Graphene Field‐Effect Nanosensor Capable of Automatic Liquid Collection/Filtering for Cytokine Storm Biomarker Monitoring in Undiluted Sweat

Cong Huang,Dongliang Li,Jialin Liu,Siyu Hou,Weisong Yang,Hao Wang,Junduo Wang,Ziran Wang,Feiran Li,Zhuang Hao,Suichu Huang,Xuezeng Zhao,PingAn Hu,Yunlu Pan
DOI: https://doi.org/10.1002/adfm.202309447
IF: 19
2023-11-28
Advanced Functional Materials
Abstract:A wearable detection system that integrates a Janus membrane and aptamer‐modified graphene field‐effect transistor sensors, enabling the detection of low‐concentration cytokines in undiluted sweat samples, with a detection range of 0.5 to 500 pM, and a detection limit of 0.31 pM. Meanwhile, it maintains stable performance even after undergoing a deformation with a bending radius of 20 μm. A wearable sensor capable of directly detecting cytokines in external secretions external to the human body is pivotal for gauging the intensity of the immune response and circumventing inflammatory storms, a significant clinical concern. The detection of low‐concentration cytokines is often hampered due to interference from impurities in secretions. Addressing this challenge, a wearable detection system is developed by integrating a Janus membrane with water auto‐collection/filtering capabilities, and aptamer‐modified graphene field‐effect transistor sensors, enabling the detection of low‐concentration cytokines in undiluted sweat samples. The Janus membrane can automatically filter external secretions and transport them to the sensor surface, effectively eliminating impurity interference and enhancing the sensor's detection capabilities. The device can sensitively detect cytokines (such as TNF‐α, a marker for inflammation and cancer) in undiluted sweat, with a detection range spanning 0.5 to 500 pM, and a detection limit reaching 0.31 pM. The ultra‐flexibility of the sensor is also verified, maintaining stable electrical properties even after enduring up to 50 extreme deformations. These findings indicate that the wearable detection system has the potential to realize low‐concentration cytokines monitoring in the sweat of inflammatory patients, to assist the healthcare system in controlling the body's immune status.
materials science, multidisciplinary,chemistry, physical,physics, applied, condensed matter,nanoscience & nanotechnology
What problem does this paper attempt to address?
The problem that this paper attempts to solve is the challenge of directly detecting low - concentration cytokines (such as TNF - α) in undiluted human sweat. Specifically, the paper focuses on how to overcome the interference of various impurities in sweat and achieve high - sensitivity and accurate detection of cytokines. This technology is of great significance for monitoring immune responses, preventing inflammatory storms and other clinical problems. ### Key problems solved by the paper 1. **Detection of low - concentration cytokines**: - The concentration of cytokines in human secretions is extremely low, and it is difficult for traditional detection methods to achieve efficient detection. - The paper proposes a wearable sensor based on graphene field - effect transistors (GFETs), which can detect low - concentration cytokines in undiluted sweat. 2. **Impurity interference problem**: - Sweat contains various impurities, such as oils, skin fragments, and dust, which will interfere with the detection of cytokines. - The paper designs a Janus membrane, which can automatically collect and filter sweat, effectively remove impurities, and improve the detection performance of the sensor. 3. **Wearability and flexibility**: - Wearable devices need to have a high degree of flexibility and comfort to adapt to the complex contours of human skin. - The sensor in the paper uses an ultra - thin polyethylene terephthalate (PET) substrate, which can withstand extreme deformation, including a bending radius of 20 μm, a folding angle of 150°, and shrinking to 3% of the original size. ### Technical solutions 1. **Janus membrane**: - Using the surface energy gradient, the Janus membrane can automatically collect and transport sweat and filter out most impurities during the transportation process. - One side of the membrane is hydrophilic, and the other side is hydrophobic. Through this design, the directional transmission of sweat is achieved. 2. **Graphene field - effect transistors (GFETs)**: - The sensor part is composed of graphene field - effect transistors. By modifying specific aptamers, it can specifically bind to target cytokines (such as TNF - α). - After the aptamer binds to the cytokine, it will cause a change in the charge carriers on the graphene surface, thereby changing the output characteristic curve of the GFET and achieving the detection of the cytokine. 3. **Integrated detection system**: - In addition to the sensor part, the paper also designs a supporting detection circuit system, including functional modules such as signal amplification, conversion, processing, display, and Wi - Fi connection. - Through these modules, the electrical signals detected by the sensor can be transmitted in real - time to mobile devices such as mobile phones, achieving remote monitoring. ### Experimental results - **Detection range and sensitivity**: - The sensor can detect TNF - α in the range of 0.5 to 500 pM, and the detection limit reaches 0.31 pM. - Even in undiluted real - world sweat samples, the sensor also shows high sensitivity and accuracy. - **Mechanical properties**: - After 50 extreme deformations, the sensor can still maintain stable electrical performance, showing excellent mechanical stability and wearability. ### Conclusion The paper proposes a highly sensitive wearable detection system that can automatically collect and filter sweat and achieve the detection of low - concentration cytokines in undiluted real - world sweat. This technology not only overcomes the limitations of traditional detection methods but also provides new means for monitoring immune responses and controlling inflammatory storms.